Availability: | |
---|---|
Quantity: | |
WS1110W
SAINTBOND
WS1110W weighing pad (The weighing pad’s model can be changed according to customer’s request)
Features:
Aluminum-alloy; Ultra thin weigh pad design; Easily mounted / unmounted slope; Hermetically sealed, suits different environment;Works both dynamically and statically;Can be used to measure axle weight and whole vehicle weight when two or four weigh-pad connected together.
Wireless Specification | |||
A/D Conversion Method | Σ-Δ 24bit | ||
Input Signal Range | –19.5mV~19.5mV | ||
Load Cell Excitation | DC 5V | ||
Max. Connection Number Of Load Cell | 1~4 | ||
Load Cell Connection Mode | 4 wire | ||
Operating Temperature | -10°C~40 °C | ||
Allowable Working Temperature | -40 °C ~70 ° C | ||
Wireless Transmission Frequency | 430MHz to 470MHz | ||
Wireless Transmission Distance | 800 meters (In Open Place) | ||
Weighing Pad Product Parameters | |||
Rated Load:10/15/20t | Compensated temp.range(℃): -10~+50 | ||
Dynamic Error (%F.S): 3 (5~10km/h) | Static error (%F.S):0.1~0.3 | ||
Static Comprehensive Error(%F.S): 0.1~0.5 | Insulation resistance(MΩ): ≥5000(100VDC) | ||
Rated Output(Mv/V): 1.0±0.1 | Use temp.range(℃): -30~+80 | ||
Non-Linearity(%F.S): 0.2 | Temp.effect on zero(F.S/10℃): 0.03 | ||
Error On Corners(%F.S): 0.2 | Temp.effect on span(F.S/10℃): 0.05 | ||
Repeatariy(%F.S): 0.05 | Safe overload(%): 120 | ||
Zero Balance(%F.S): ±1 | Ultimate overload(%): 150 | ||
Excitation Voltage(VDC): 9~15 | Net weight(kg): 28 | ||
Recommended Voltage(V): 10 | Defend grade: IP66 | ||
Dynamic Comprehensive Error(%F.S): | 1.5 (1~5km/h) 3 (5~10km/h) |
WS1110W weighing pad (The weighing pad’s model can be changed according to customer’s request)
Features:
Aluminum-alloy; Ultra thin weigh pad design; Easily mounted / unmounted slope; Hermetically sealed, suits different environment;Works both dynamically and statically;Can be used to measure axle weight and whole vehicle weight when two or four weigh-pad connected together.
Wireless Specification | |||
A/D Conversion Method | Σ-Δ 24bit | ||
Input Signal Range | –19.5mV~19.5mV | ||
Load Cell Excitation | DC 5V | ||
Max. Connection Number Of Load Cell | 1~4 | ||
Load Cell Connection Mode | 4 wire | ||
Operating Temperature | -10°C~40 °C | ||
Allowable Working Temperature | -40 °C ~70 ° C | ||
Wireless Transmission Frequency | 430MHz to 470MHz | ||
Wireless Transmission Distance | 800 meters (In Open Place) | ||
Weighing Pad Product Parameters | |||
Rated Load:10/15/20t | Compensated temp.range(℃): -10~+50 | ||
Dynamic Error (%F.S): 3 (5~10km/h) | Static error (%F.S):0.1~0.3 | ||
Static Comprehensive Error(%F.S): 0.1~0.5 | Insulation resistance(MΩ): ≥5000(100VDC) | ||
Rated Output(Mv/V): 1.0±0.1 | Use temp.range(℃): -30~+80 | ||
Non-Linearity(%F.S): 0.2 | Temp.effect on zero(F.S/10℃): 0.03 | ||
Error On Corners(%F.S): 0.2 | Temp.effect on span(F.S/10℃): 0.05 | ||
Repeatariy(%F.S): 0.05 | Safe overload(%): 120 | ||
Zero Balance(%F.S): ±1 | Ultimate overload(%): 150 | ||
Excitation Voltage(VDC): 9~15 | Net weight(kg): 28 | ||
Recommended Voltage(V): 10 | Defend grade: IP66 | ||
Dynamic Comprehensive Error(%F.S): | 1.5 (1~5km/h) 3 (5~10km/h) |