WI0551
SAINTBOND
Introduction:
●Stable and reliable performance; Accurate and intuitive measurement;Load Cell nonlinear compensation function;
●Matching with various sensors with linear output characteristics;
●Multi alarm mode selection and relay control output;
●Automatic / manual reset, peak memory;
●Serial RS-232 / 485 bidirectional communication and printing interface;
●Input power: 220V / 50Hz or 24VDC;
●Opening size 150 (L)×120(W)×75 (H) (L×D×h);
Technical Parameters:
1. Input mode: MV signal, standard transmission signal or frequency signal;
2. Measurement accuracy: ± 0.02% (FS) / (23 ℃ ± 5 ℃);
3. Sampling speed: 10 times / second; 80 times / second (specify when ordering);
4.Display mode: 5-bit 0.8-inch high brightness LED digital tube, with four levels of brightness adjustable;
Display range: - 19999~99999;
5. Alarm output: up to four channels, and each channel can select lower limit, upper and lower limits, and upper and lower limit interval alarm;
Contact capacity: (3a / 220VAC);
6. Analog output: 0-5V, 1-5V, 4-20mA, etc;
7. Communication interface: Standard Serial RS-232 / 485 bidirectional interface, multi machine address range 0-99;
Baud rate 2400-38400bps;
8. Power supply: 220VAC / 50Hz or 24VDC optional; Power consumption: less than 5VA;
9. Opening size:150 (L)×120(W)×75 (H) (L×D×h);
Notes:
1.The input wire of the sensor should not be too long, and shielded wire should be used as much as possible;
2.Before the instrument is put into use, please power on and preheat for 10-30 minutes to obtain better stability;
3.The instrument has been calibrated before leaving the factory. Generally, the user does not need to calibrate again. If there is error in the display value, please ensure that there is a standard force source or reference source to calibrate the instrument according to this manual;
4.The applicable ambient temperature of the instrument is - 20 ~ + 70℃ and the humidity is below 85%; Exceeding this use range may cause the instrument to not work normally;
5. When using, keep away from strong electromagnetic interference. If it is necessary to work in this environment, please take appropriate anti-interference measures;
6.Avoid the instrument working under strong vibration and impact, and prevent a large amount of dust and harmful chemicals from invading;
7.After long-term use, the instrument shall be regularly verified and calibrated to the manufacturer or relevant measurement department.
Product name | WI0551 Controller Scale Weighing Indicator Control Indicator Weighing Load Cell |
Brand | SAINTBOND |
Market | All over the world |
Features | High precision and stable performance |
Advantage | 0EM/ODM |
Sample Lead Time | 5~ 40Days |
Sample price | The price is different according to product capacity |
Custom Design | Welcome |
Form of sale | Factory supply |
Introduction:
●Stable and reliable performance; Accurate and intuitive measurement;Load Cell nonlinear compensation function;
●Matching with various sensors with linear output characteristics;
●Multi alarm mode selection and relay control output;
●Automatic / manual reset, peak memory;
●Serial RS-232 / 485 bidirectional communication and printing interface;
●Input power: 220V / 50Hz or 24VDC;
●Opening size 150 (L)×120(W)×75 (H) (L×D×h);
Technical Parameters:
1. Input mode: MV signal, standard transmission signal or frequency signal;
2. Measurement accuracy: ± 0.02% (FS) / (23 ℃ ± 5 ℃);
3. Sampling speed: 10 times / second; 80 times / second (specify when ordering);
4.Display mode: 5-bit 0.8-inch high brightness LED digital tube, with four levels of brightness adjustable;
Display range: - 19999~99999;
5. Alarm output: up to four channels, and each channel can select lower limit, upper and lower limits, and upper and lower limit interval alarm;
Contact capacity: (3a / 220VAC);
6. Analog output: 0-5V, 1-5V, 4-20mA, etc;
7. Communication interface: Standard Serial RS-232 / 485 bidirectional interface, multi machine address range 0-99;
Baud rate 2400-38400bps;
8. Power supply: 220VAC / 50Hz or 24VDC optional; Power consumption: less than 5VA;
9. Opening size:150 (L)×120(W)×75 (H) (L×D×h);
Notes:
1.The input wire of the sensor should not be too long, and shielded wire should be used as much as possible;
2.Before the instrument is put into use, please power on and preheat for 10-30 minutes to obtain better stability;
3.The instrument has been calibrated before leaving the factory. Generally, the user does not need to calibrate again. If there is error in the display value, please ensure that there is a standard force source or reference source to calibrate the instrument according to this manual;
4.The applicable ambient temperature of the instrument is - 20 ~ + 70℃ and the humidity is below 85%; Exceeding this use range may cause the instrument to not work normally;
5. When using, keep away from strong electromagnetic interference. If it is necessary to work in this environment, please take appropriate anti-interference measures;
6.Avoid the instrument working under strong vibration and impact, and prevent a large amount of dust and harmful chemicals from invading;
7.After long-term use, the instrument shall be regularly verified and calibrated to the manufacturer or relevant measurement department.
Product name | WI0551 Controller Scale Weighing Indicator Control Indicator Weighing Load Cell |
Brand | SAINTBOND |
Market | All over the world |
Features | High precision and stable performance |
Advantage | 0EM/ODM |
Sample Lead Time | 5~ 40Days |
Sample price | The price is different according to product capacity |
Custom Design | Welcome |
Form of sale | Factory supply |