Availability: | |
---|---|
Quantity: | |
WS1130
SAINTBOND
Outline Dimension (mm):
Note: Both cable and spring tube are available on requests.
Features:
lLight in weight, and convenient transportation.
lIntegral flat plate construction, high frequency in dynamic response, and high precision.
lApplied special treatment, offering high protection class that are suitable for all kinds of environments.
lAdopted special material in aero-industry, with good anti-over loading ability.
lAssembled with rubber handles, avoided destroying of the handles.
lProvided with spring tube, protecting the cables from being crushed.
lMounted with connector and protection block, easy for changing of cables.
lCompleted with dovetail approach, offering tight connection of the approach and the scale.
lEasy for loading on/off of the vehicles.
Applications:
lLoad control and weighing for the vehicles;
lMeasuring the weight and barycenter of aeroplane;
lMeasuring weight for special purpose;
Specification:
Output Sensitivity: | 1±0.2m V/V | Temp., Compensated: | -10~+50℃ |
Combined Error : | 0.2(%ld | Temp., Operating: | -40~+80℃ |
Non-Linearity: | 0.2%ld | Excitation, Recommended (V): | 9~15DC |
Repeatability: | 0.1%ld | Excitation, Max.(V): | 20DC |
Input Resistance: | 3120±40Ω | Safe Overload: | 120%FS |
Ouput Resistance: | 2800±10Ω | Ultimate Overload: | 150%FS |
Insulation Resistance: | ≥5000(100VDC) | Protection Class: | IP66 |
Zero Balance : | 4~10%FS | Cable Spec.: | 4-wire shield cable |
Tem. Effect On Sensitivity : | 0.1%FS/10℃ | Max. Load For Single Point (t): | 10t |
Temp. Effect On Zero: | 0.1%FS/10℃ | Rated Capacity (t): | 15t |
Outline Dimension (mm):
Note: Both cable and spring tube are available on requests.
Features:
lLight in weight, and convenient transportation.
lIntegral flat plate construction, high frequency in dynamic response, and high precision.
lApplied special treatment, offering high protection class that are suitable for all kinds of environments.
lAdopted special material in aero-industry, with good anti-over loading ability.
lAssembled with rubber handles, avoided destroying of the handles.
lProvided with spring tube, protecting the cables from being crushed.
lMounted with connector and protection block, easy for changing of cables.
lCompleted with dovetail approach, offering tight connection of the approach and the scale.
lEasy for loading on/off of the vehicles.
Applications:
lLoad control and weighing for the vehicles;
lMeasuring the weight and barycenter of aeroplane;
lMeasuring weight for special purpose;
Specification:
Output Sensitivity: | 1±0.2m V/V | Temp., Compensated: | -10~+50℃ |
Combined Error : | 0.2(%ld | Temp., Operating: | -40~+80℃ |
Non-Linearity: | 0.2%ld | Excitation, Recommended (V): | 9~15DC |
Repeatability: | 0.1%ld | Excitation, Max.(V): | 20DC |
Input Resistance: | 3120±40Ω | Safe Overload: | 120%FS |
Ouput Resistance: | 2800±10Ω | Ultimate Overload: | 150%FS |
Insulation Resistance: | ≥5000(100VDC) | Protection Class: | IP66 |
Zero Balance : | 4~10%FS | Cable Spec.: | 4-wire shield cable |
Tem. Effect On Sensitivity : | 0.1%FS/10℃ | Max. Load For Single Point (t): | 10t |
Temp. Effect On Zero: | 0.1%FS/10℃ | Rated Capacity (t): | 15t |