Availability: | |
---|---|
Quantity: | |
LCT021
SAINTBOND
Description:
The LCT021 is a rotating torque transducer manufactured using a key slot design, suitable for measuring rotational torsion up to 4000rpm. The LCT021 sensor body is produced from stainless steel with an aluminium housing. This transducer has been designed for the measurement of static and dynamic torque on rotating machines, test benches and automatic tightening systems.
NOTE: Torque transducers are supplied calibrated in a single direction as standard, either clockwise or anti-clockwise. If calibration in both directions is required, please specify this on enquiring.
Applications:
●Test machines;
●Process control;
Loading Mode:
Dimension:
Cap. | ΦA | B | C | D | E | Keyslot | F | G | H | I | L | M | N |
(Nm) | (mm) | ||||||||||||
0.5 | 16h6 | 30 | 25 | 5 | 3 | UNI6604 from A5×5 | 2.5 | 64 | 63.5 | 52 | 26 | 32 | 44 |
2.5 | |||||||||||||
5 | |||||||||||||
10 | |||||||||||||
25 | |||||||||||||
50 | |||||||||||||
100 | 25h6 | 40 | 35 | 8 | 4 | UNI6604 from A 8×7 | |||||||
250 | |||||||||||||
500 | |||||||||||||
1000 | 50h6 | 100 | 80 | 14 | 5.5 | UNI6604 from A 14×9 | 5 | 100 | 100 | 100 | 41 | 80 | 80 |
3000 | |||||||||||||
5000 |
Technical Parameter:
Cap. | 0.5/2.5/5/10/25/50/100/250/500/1000/3000/5000Nm | ||
Output sensitivity | 0.5Nm 1mV/V ; 2.5/5/10/25/50/100/250/500/1000/3000/5000Nm 2mV/V | ||
Zero output | ±1%FS | Input resistance | 750±10Ω |
Nonlinear | ±0.1,±0.3%FS | Output resistance | 750±5Ω |
Lagging | ≤±0.05%FS | Insulation resistance | ≥5000MΩ/100VDC |
Repeatability | ≤±0.05%FS | Service voltage | 5-10V |
Creep (30 Minutes) | ≤±0.03%FS | Maximum voltage | 15V |
Sensitivity temp. drift | 0.03%FS/10℃ | Temp. compensation range | -10~+60℃ |
Zero temp.drift | 0.03%FS/10℃ | Working temperature | -20~+80℃ |
Material | Stainless stainless | Safe Overload | 150% |
Alloy steel | Ultimate overload | 300% | |
Cable size | φ5.2×3m |
Applications:
The LCT021 measures CLOCKWISE torque with a POSITIVE output in tension or ANTICLOCKWISE torque with NEGATIVE output in tension.
The assembly of the couplings to the LCT021 must be done whilst disconnected from the machine (system) with the transducer only connected to a display, thus verifying in real time that no unwanted torque, bending or tension are generated which may overload the transducer.
Mount the LCT021 with its couplings on the support, align the system along its own axis and connect the system. Even in this phase, care must be taken that the measure showed on the display does not exceed the nominal torque rating of the transducer.
WARNING: Avoid accidental overloading that may irreparably damage the LCT021.
WARNING: Protect the cable from contact with high tension cables, inverters, generators and/or solenoid valves.
Product name | LCT021 Rotary And Static Torque Measurement Torque Measuring Instrument Transducer To Measure Dynamic Torque |
Brand | SAINTBOND |
Market | All over the world |
Features | High precision and stable performance |
Advantage | 0EM/ODM |
Sample Lead Time | 5~ 40Days |
Sample price | The price is different according to product capacity |
Custom Design | Welcome |
Form of sale | Factory supply |
Description:
The LCT021 is a rotating torque transducer manufactured using a key slot design, suitable for measuring rotational torsion up to 4000rpm. The LCT021 sensor body is produced from stainless steel with an aluminium housing. This transducer has been designed for the measurement of static and dynamic torque on rotating machines, test benches and automatic tightening systems.
NOTE: Torque transducers are supplied calibrated in a single direction as standard, either clockwise or anti-clockwise. If calibration in both directions is required, please specify this on enquiring.
Applications:
●Test machines;
●Process control;
Loading Mode:
Dimension:
Cap. | ΦA | B | C | D | E | Keyslot | F | G | H | I | L | M | N |
(Nm) | (mm) | ||||||||||||
0.5 | 16h6 | 30 | 25 | 5 | 3 | UNI6604 from A5×5 | 2.5 | 64 | 63.5 | 52 | 26 | 32 | 44 |
2.5 | |||||||||||||
5 | |||||||||||||
10 | |||||||||||||
25 | |||||||||||||
50 | |||||||||||||
100 | 25h6 | 40 | 35 | 8 | 4 | UNI6604 from A 8×7 | |||||||
250 | |||||||||||||
500 | |||||||||||||
1000 | 50h6 | 100 | 80 | 14 | 5.5 | UNI6604 from A 14×9 | 5 | 100 | 100 | 100 | 41 | 80 | 80 |
3000 | |||||||||||||
5000 |
Technical Parameter:
Cap. | 0.5/2.5/5/10/25/50/100/250/500/1000/3000/5000Nm | ||
Output sensitivity | 0.5Nm 1mV/V ; 2.5/5/10/25/50/100/250/500/1000/3000/5000Nm 2mV/V | ||
Zero output | ±1%FS | Input resistance | 750±10Ω |
Nonlinear | ±0.1,±0.3%FS | Output resistance | 750±5Ω |
Lagging | ≤±0.05%FS | Insulation resistance | ≥5000MΩ/100VDC |
Repeatability | ≤±0.05%FS | Service voltage | 5-10V |
Creep (30 Minutes) | ≤±0.03%FS | Maximum voltage | 15V |
Sensitivity temp. drift | 0.03%FS/10℃ | Temp. compensation range | -10~+60℃ |
Zero temp.drift | 0.03%FS/10℃ | Working temperature | -20~+80℃ |
Material | Stainless stainless | Safe Overload | 150% |
Alloy steel | Ultimate overload | 300% | |
Cable size | φ5.2×3m |
Applications:
The LCT021 measures CLOCKWISE torque with a POSITIVE output in tension or ANTICLOCKWISE torque with NEGATIVE output in tension.
The assembly of the couplings to the LCT021 must be done whilst disconnected from the machine (system) with the transducer only connected to a display, thus verifying in real time that no unwanted torque, bending or tension are generated which may overload the transducer.
Mount the LCT021 with its couplings on the support, align the system along its own axis and connect the system. Even in this phase, care must be taken that the measure showed on the display does not exceed the nominal torque rating of the transducer.
WARNING: Avoid accidental overloading that may irreparably damage the LCT021.
WARNING: Protect the cable from contact with high tension cables, inverters, generators and/or solenoid valves.
Product name | LCT021 Rotary And Static Torque Measurement Torque Measuring Instrument Transducer To Measure Dynamic Torque |
Brand | SAINTBOND |
Market | All over the world |
Features | High precision and stable performance |
Advantage | 0EM/ODM |
Sample Lead Time | 5~ 40Days |
Sample price | The price is different according to product capacity |
Custom Design | Welcome |
Form of sale | Factory supply |