SAINTBOND
Features:
Used in elevators for safety, traffic control and energy control; Low profile; Amplified output (0.4 - 12.4Vdc); Located under the inner cage.
Outline Dimensions (in mm)
Dimensions(In mm)
Load cell for elevators LC714 is a low-profile, pancake-type load cell, especially designed for use in elevators. Model LC714 is equipped with a built-in amplifier and is commonly placed between the inner and outer cages of the elevators cabin. The number of load cells required depends upon the cabin size and ranges from two to eight load cells (some may be dummies). Model LC714 is used for 3 reasons:
1.Safety - The load cell is an over load sensor, that indicates if the weight in the elevator passes a certain value that was allowed by the elevator designers. It also can be used prevent a child using the elevator, if the elevator control system does not allow it to drive if a demand from a low weight user (a child) is made.
2.Traffic Control - The load cell is a sensor that transmits
load information to the elevator control system, used in buildings with more than one elevator. This information can be used to decide which elevator to send to a user, taking into account the load in the elevator, in order to shorten waiting time or prevent full/semi full elevators from stopping.
3.Energy Saving - The load cell is a sensor that transmits load information to the elevator control system, used in buildings with more than one elevator. This information is used in energy saving algorithms of the control system. A common elevator is constructed from an external cage with an internal cabin. The cabin is positioned on several rubber dampers, according to its size. Load cells (or dummies) are located between these dampers and the cabin (under the cabin). The number of load cells depends on the design.
Technical Parameter:
Rated Load: | 500kg | Operating Temp. Range: | -30~+70℃ |
Sensitivity: | (1.0±0.1%) mV/V | Maximum Safe Over Load: | 150%F.S |
Combined Error: | ±5% F.S | Ultimate Over Load: | 300%F.S |
Creep Error(30min): | ±0.02% F.S | Recommend Excitation Vol.: | 10~12V DC |
Zero Balance: | ±1% F.S | Maximum Excitation Vol.: | 15V DC |
Temp. Effect On Zero: | ±0.02% F.S/10℃ | Sealing Class: | IP65 |
Temp. Effect On Span: | ±0.02% F.S/10℃ | Element Material: | Alloy Steel, Stainless Steel |
Input Resistance: | 385±5Ω | Cable: | Length=L:5m |
Output Resistance: | 352±2Ω | Citation: | GB/T7551-1997/ OIML R60 |
Insulation Resistance: | ≥5000MΩ | Mode Of Connection: | Red(Input+),Green(Output+), Black(Input-),White(Output-) |
Product name | LC6009 Washer Load Cell Sensor Elevator Load Cell 500kg |
Brand | SAINTBOND |
Market | All over the world |
Features | High precision and stable performance |
Advantage | 0EM/ODM |
Sample Lead Time | 5~ 40Days |
Sample price | The price is different according to product capacity |
Custom Design | Welcome |
Form of sale | Factory supply |
Features:
Used in elevators for safety, traffic control and energy control; Low profile; Amplified output (0.4 - 12.4Vdc); Located under the inner cage.
Outline Dimensions (in mm)
Dimensions(In mm)
Load cell for elevators LC714 is a low-profile, pancake-type load cell, especially designed for use in elevators. Model LC714 is equipped with a built-in amplifier and is commonly placed between the inner and outer cages of the elevators cabin. The number of load cells required depends upon the cabin size and ranges from two to eight load cells (some may be dummies). Model LC714 is used for 3 reasons:
1.Safety - The load cell is an over load sensor, that indicates if the weight in the elevator passes a certain value that was allowed by the elevator designers. It also can be used prevent a child using the elevator, if the elevator control system does not allow it to drive if a demand from a low weight user (a child) is made.
2.Traffic Control - The load cell is a sensor that transmits
load information to the elevator control system, used in buildings with more than one elevator. This information can be used to decide which elevator to send to a user, taking into account the load in the elevator, in order to shorten waiting time or prevent full/semi full elevators from stopping.
3.Energy Saving - The load cell is a sensor that transmits load information to the elevator control system, used in buildings with more than one elevator. This information is used in energy saving algorithms of the control system. A common elevator is constructed from an external cage with an internal cabin. The cabin is positioned on several rubber dampers, according to its size. Load cells (or dummies) are located between these dampers and the cabin (under the cabin). The number of load cells depends on the design.
Technical Parameter:
Rated Load: | 500kg | Operating Temp. Range: | -30~+70℃ |
Sensitivity: | (1.0±0.1%) mV/V | Maximum Safe Over Load: | 150%F.S |
Combined Error: | ±5% F.S | Ultimate Over Load: | 300%F.S |
Creep Error(30min): | ±0.02% F.S | Recommend Excitation Vol.: | 10~12V DC |
Zero Balance: | ±1% F.S | Maximum Excitation Vol.: | 15V DC |
Temp. Effect On Zero: | ±0.02% F.S/10℃ | Sealing Class: | IP65 |
Temp. Effect On Span: | ±0.02% F.S/10℃ | Element Material: | Alloy Steel, Stainless Steel |
Input Resistance: | 385±5Ω | Cable: | Length=L:5m |
Output Resistance: | 352±2Ω | Citation: | GB/T7551-1997/ OIML R60 |
Insulation Resistance: | ≥5000MΩ | Mode Of Connection: | Red(Input+),Green(Output+), Black(Input-),White(Output-) |
Product name | LC6009 Washer Load Cell Sensor Elevator Load Cell 500kg |
Brand | SAINTBOND |
Market | All over the world |
Features | High precision and stable performance |
Advantage | 0EM/ODM |
Sample Lead Time | 5~ 40Days |
Sample price | The price is different according to product capacity |
Custom Design | Welcome |
Form of sale | Factory supply |