Availability: | |
---|---|
Quantity: | |
LC4599
SAINTBOND
Dimensions: Unit: mm
Capacity | ΦA | ΦB | H | N-M | H1 |
(Ton) | (mm) | ||||
0.3~5t | 58 | 42 | 75 | 4-M8 | 17 |
10~30t | 88 | 65 | 130 | 6-M12 | 30 |
40~60t | 128 | 90 | 140 | 8-M12 | 35 |
80~150t | 168 | 125 | 160 | 8-M16 | 45 |
Note:
lNote: the parameters noted in this page are only for model selection reference. Please refer to the confirmation at the time of ordering for details!
lThe size can be customized according to customers' requirements;
Technical Parameter:
Rated Load: | 300kg~150t | ||
Sensitivity: | 1.0~2.0mV/V | Operating Temp. Range: | -30~+70℃ |
Combined Error: | ±0.1% F.S | Max. Safe Over Load: | 150%F.S |
Creep Error(30min): | ±0.05% F.S | Ultimate Over Load: | 200%F.S |
Zero Balance: | ±1% F.S | Recommend Excitation Vol.: | 10~12V DC |
Temp. Effect On Zero: | ±0.02% F.S/10℃ | Max. Excitation Voltage: | 15V DC |
Temp. Effect On Span: | ±0.02% F.S/10℃ | Sealing Class: | IP67 |
Input Resistance: | 380±30Ω | Element Material: | Alloy Steel/Stainless Steel |
Output Resistance: | 350±2Ω | Cable: | Length=L:12m |
Insulation Resistance: | ≥5000MΩ | Citation: | GB/T7551-2008/ OIML R60 |
Product name | LC4599 MTX Load Cells Column Canister Compression Load Cell |
Brand | SAINTBOND |
Market | All over the world |
Features | High precision and stable performance |
Advantage | 0EM/ODM |
Sample Lead Time | 5~ 40Days |
Sample price | The price is different according to product capacity |
Custom Design | Welcome |
Form of sale | Factory supply |
Dimensions: Unit: mm
Capacity | ΦA | ΦB | H | N-M | H1 |
(Ton) | (mm) | ||||
0.3~5t | 58 | 42 | 75 | 4-M8 | 17 |
10~30t | 88 | 65 | 130 | 6-M12 | 30 |
40~60t | 128 | 90 | 140 | 8-M12 | 35 |
80~150t | 168 | 125 | 160 | 8-M16 | 45 |
Note:
lNote: the parameters noted in this page are only for model selection reference. Please refer to the confirmation at the time of ordering for details!
lThe size can be customized according to customers' requirements;
Technical Parameter:
Rated Load: | 300kg~150t | ||
Sensitivity: | 1.0~2.0mV/V | Operating Temp. Range: | -30~+70℃ |
Combined Error: | ±0.1% F.S | Max. Safe Over Load: | 150%F.S |
Creep Error(30min): | ±0.05% F.S | Ultimate Over Load: | 200%F.S |
Zero Balance: | ±1% F.S | Recommend Excitation Vol.: | 10~12V DC |
Temp. Effect On Zero: | ±0.02% F.S/10℃ | Max. Excitation Voltage: | 15V DC |
Temp. Effect On Span: | ±0.02% F.S/10℃ | Sealing Class: | IP67 |
Input Resistance: | 380±30Ω | Element Material: | Alloy Steel/Stainless Steel |
Output Resistance: | 350±2Ω | Cable: | Length=L:12m |
Insulation Resistance: | ≥5000MΩ | Citation: | GB/T7551-2008/ OIML R60 |
Product name | LC4599 MTX Load Cells Column Canister Compression Load Cell |
Brand | SAINTBOND |
Market | All over the world |
Features | High precision and stable performance |
Advantage | 0EM/ODM |
Sample Lead Time | 5~ 40Days |
Sample price | The price is different according to product capacity |
Custom Design | Welcome |