L6T
SAINTBOND
Short Description:
◎Aluminium-Alloy IP65 single point load cell;
◎Colourless anodized;
◎Suitable for single or double load cell structured platform scales;
◎Recommended platform size: 600 x 600 mm;
Dimensions in mm:
Available models:
Capacity | Accuracy | Full article description | Capacity | Accuracy | Full article description |
50kg | C3/C4 | L6T-C3/C4-50kg-3B6 | 250kg | C3/C4 | L6T-C3/C4-250kg-3B6 |
75kg | C3/C4 | L6T-C3/C4-75kg-3B6 | 300kg | C3 | L6T-C3-300kg-3B6 |
100kg | C3/C4 | L6T-C3/C4-100kg-3B6 | 500kg | C3 | L6T-C3-500kg-3B6 |
150kg | C3/C4 | L6T-C3/C4-150kg-3B6 | 635kg | C3 | L6T-C3-635kg-3B6 |
200kg | C3/C4 | L6T-C3/C4-200kg-3B6 | 1000kg | C3 | L6T-C3-1000kg-3B6 |
Specification:
Accuracy class | OIML R60 C3 | OIML R60 C4 | ||
Output sensitivity (= FS) | mV/V | 2.0 ±02 | ||
Maximum capacity ( Emax) | kg | 50,75,100,150,200,250 | 300,500,635,1000 | 50,75,100,150,200,250 |
Maximum number of load cell intervals(nLC) | 3000 | 4000 | ||
Ratio of minimum LC verification interval Y = Emax / Vmin | 6500 | 15000 | 6500 | |
Combined error | %FS | ± 0.02 | ± 0.0150 | |
Minimum dead load12 | of Emax | 0% | ||
Safe overload | of Emax | 120% | ||
Ultimate overload | of Emax | 150% | ||
Zero balance | %FS | ± 2.0 | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Input resistance | Ω | 406±6 | ||
Output resistance | Ω | 350±3 | ||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Storace temperature | ℃ | -40~+70 | ||
Element matenial | Aluminium | |||
Recommended torque on fixation | N.m | M8:25 | ||
lngress protection (according to EN 60529) | IP65 |
Wiring:
◎Shielded, 6 conductor cable;
◎Cable Diameter: Φ4.8mm;
◎Standard cable length: 3m;
◎Shield not connected to element;
◎Cable jacket is PVC;
Short Description:
◎Aluminium-Alloy IP65 single point load cell;
◎Colourless anodized;
◎Suitable for single or double load cell structured platform scales;
◎Recommended platform size: 600 x 600 mm;
Dimensions in mm:
Available models:
Capacity | Accuracy | Full article description | Capacity | Accuracy | Full article description |
50kg | C3/C4 | L6T-C3/C4-50kg-3B6 | 250kg | C3/C4 | L6T-C3/C4-250kg-3B6 |
75kg | C3/C4 | L6T-C3/C4-75kg-3B6 | 300kg | C3 | L6T-C3-300kg-3B6 |
100kg | C3/C4 | L6T-C3/C4-100kg-3B6 | 500kg | C3 | L6T-C3-500kg-3B6 |
150kg | C3/C4 | L6T-C3/C4-150kg-3B6 | 635kg | C3 | L6T-C3-635kg-3B6 |
200kg | C3/C4 | L6T-C3/C4-200kg-3B6 | 1000kg | C3 | L6T-C3-1000kg-3B6 |
Specification:
Accuracy class | OIML R60 C3 | OIML R60 C4 | ||
Output sensitivity (= FS) | mV/V | 2.0 ±02 | ||
Maximum capacity ( Emax) | kg | 50,75,100,150,200,250 | 300,500,635,1000 | 50,75,100,150,200,250 |
Maximum number of load cell intervals(nLC) | 3000 | 4000 | ||
Ratio of minimum LC verification interval Y = Emax / Vmin | 6500 | 15000 | 6500 | |
Combined error | %FS | ± 0.02 | ± 0.0150 | |
Minimum dead load12 | of Emax | 0% | ||
Safe overload | of Emax | 120% | ||
Ultimate overload | of Emax | 150% | ||
Zero balance | %FS | ± 2.0 | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Input resistance | Ω | 406±6 | ||
Output resistance | Ω | 350±3 | ||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Storace temperature | ℃ | -40~+70 | ||
Element matenial | Aluminium | |||
Recommended torque on fixation | N.m | M8:25 | ||
lngress protection (according to EN 60529) | IP65 |
Wiring:
◎Shielded, 6 conductor cable;
◎Cable Diameter: Φ4.8mm;
◎Standard cable length: 3m;
◎Shield not connected to element;
◎Cable jacket is PVC;