Availability: | |
---|---|
Quantity: | |
L6L
SAINTBOND
Short Description:
◎Aluminium-Alloy IP65 single point load cell;
◎Colourless anodized;
◎Suitable for counting scales, balances, pricing scales, etc;
◎Recommended platform size: 200 x 200 mm;
Dimensions in mm:
Available models:
Capacity | Accuracy | Full article description |
5kg-200kg | C3 | L6L-C3-xxkg-1B |
Specification:
Maximum capacity(Emax) | kg | 5/8/10/15/20/30/50/80/100/150/200 |
Output sensitivity (= FS) | mVN | 2.0+0.2 |
Accuracy class | C3 | |
Combined error | %FS | ±0.02 |
Creep | %FS/30min | ±0.02 |
Temperature effect on sensitivity | %FS/10℃ | ±0.0175 |
Temperature effect on zero | %FS/10℃ | ±0.02 |
Zero balance | %FS | ±2 |
Compensated temperature | ℃ | -10~+40 |
Operating temperature | ℃ | -35~+65 |
Input resistance | Ω | 406±6 |
Output resistance | Ω | 350±3 |
Insulation resistance | MΩ | ≥ 5000(50VDC) |
Excitation, recommended voltage | V | 5~12(DC) |
Excitation maximum | V | 18(DC) |
Safe overload | of Emax | 120 |
UItimate overload | of Emax | 150 |
lngress protection (according to EN 60529) | IP65 | |
Recommended installation size | mm | 400×400 |
Corner correction | 0.02%load value/100mm |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable Diameter: Φ5.3mm;
◎Standard cable length: 1m;
◎Shield not connected to element;
◎Cable jacket is PVC;
Short Description:
◎Aluminium-Alloy IP65 single point load cell;
◎Colourless anodized;
◎Suitable for counting scales, balances, pricing scales, etc;
◎Recommended platform size: 200 x 200 mm;
Dimensions in mm:
Available models:
Capacity | Accuracy | Full article description |
5kg-200kg | C3 | L6L-C3-xxkg-1B |
Specification:
Maximum capacity(Emax) | kg | 5/8/10/15/20/30/50/80/100/150/200 |
Output sensitivity (= FS) | mVN | 2.0+0.2 |
Accuracy class | C3 | |
Combined error | %FS | ±0.02 |
Creep | %FS/30min | ±0.02 |
Temperature effect on sensitivity | %FS/10℃ | ±0.0175 |
Temperature effect on zero | %FS/10℃ | ±0.02 |
Zero balance | %FS | ±2 |
Compensated temperature | ℃ | -10~+40 |
Operating temperature | ℃ | -35~+65 |
Input resistance | Ω | 406±6 |
Output resistance | Ω | 350±3 |
Insulation resistance | MΩ | ≥ 5000(50VDC) |
Excitation, recommended voltage | V | 5~12(DC) |
Excitation maximum | V | 18(DC) |
Safe overload | of Emax | 120 |
UItimate overload | of Emax | 150 |
lngress protection (according to EN 60529) | IP65 | |
Recommended installation size | mm | 400×400 |
Corner correction | 0.02%load value/100mm |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable Diameter: Φ5.3mm;
◎Standard cable length: 1m;
◎Shield not connected to element;
◎Cable jacket is PVC;