L6J
SAINTBOND
Short Description:
◎Aluminium-Alloy IP65 single point load cell;
◎Colourless anodized;
◎Suitable for single or double load cell structured platform scales;
◎Recommended platform size: 200 x 200 mm;
Dimensions in mm:
Available models:
Capacity | Accuracy | Full article description |
2kg | C3D | L6J-C3D-2kg-0.45B |
3kg | C3D | L6J-C3D-3kg-0.45B |
5kg | C3D | L6J-C3D-5kg-0.45B |
8kg | C3D | L6J-C3D-8kg-0.45B |
15kg | C3D | L6J-C3D-15kg-0.45B |
20kg | C3D | L6J-C3D-20kg-0.45B |
Specification:
Accuracy class | C3D | |
Output sensitivity(= FS) | mVN | 1.5 ±0.2 |
Maximum capacity (Emax) | kg | 2,3,5,8,10,15,20 |
Maximum number of load cell intervals (nLC) | 2500 | |
Ratio of minimum LC verification interval Y = Emax / Vmin | 5000 | |
Combined error | %FS | ± 0.0280 |
Minimum dead load | of Emax | 0% |
Safe overload | of Emax | 150% |
Ultimate overload | of Emax | 300% |
Zero balance | %FS | ±2.0 |
Excitation, recommended voltage | V | 5~12(DC) |
Excitation maximum | V | 18(DC) |
Input resistance | Ω | 406±6 |
Output resistance | Ω | 350 ±3 |
Insulation resistance | MΩ | ≥ 5000(50VDC) |
Compensated temperature | ℃ | -10~+40 |
Operating temperature | ℃ | -35~+65 |
Storage temperature | ℃ | -40~+70 |
Element material | Aluminium | |
Recommended torque on fixation | N.m | M8:25 |
lngress protection (according to EN 60529) | IP65 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable Diameter: Φ3mm;
◎Standard cable length: 0.45m;
◎Shield not connected to element;
◎Cable jacket is PVC;
Short Description:
◎Aluminium-Alloy IP65 single point load cell;
◎Colourless anodized;
◎Suitable for single or double load cell structured platform scales;
◎Recommended platform size: 200 x 200 mm;
Dimensions in mm:
Available models:
Capacity | Accuracy | Full article description |
2kg | C3D | L6J-C3D-2kg-0.45B |
3kg | C3D | L6J-C3D-3kg-0.45B |
5kg | C3D | L6J-C3D-5kg-0.45B |
8kg | C3D | L6J-C3D-8kg-0.45B |
15kg | C3D | L6J-C3D-15kg-0.45B |
20kg | C3D | L6J-C3D-20kg-0.45B |
Specification:
Accuracy class | C3D | |
Output sensitivity(= FS) | mVN | 1.5 ±0.2 |
Maximum capacity (Emax) | kg | 2,3,5,8,10,15,20 |
Maximum number of load cell intervals (nLC) | 2500 | |
Ratio of minimum LC verification interval Y = Emax / Vmin | 5000 | |
Combined error | %FS | ± 0.0280 |
Minimum dead load | of Emax | 0% |
Safe overload | of Emax | 150% |
Ultimate overload | of Emax | 300% |
Zero balance | %FS | ±2.0 |
Excitation, recommended voltage | V | 5~12(DC) |
Excitation maximum | V | 18(DC) |
Input resistance | Ω | 406±6 |
Output resistance | Ω | 350 ±3 |
Insulation resistance | MΩ | ≥ 5000(50VDC) |
Compensated temperature | ℃ | -10~+40 |
Operating temperature | ℃ | -35~+65 |
Storage temperature | ℃ | -40~+70 |
Element material | Aluminium | |
Recommended torque on fixation | N.m | M8:25 |
lngress protection (according to EN 60529) | IP65 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable Diameter: Φ3mm;
◎Standard cable length: 0.45m;
◎Shield not connected to element;
◎Cable jacket is PVC;