Availability: | |
---|---|
Quantity: | |
L6G
SAINTBOND
Short Description:
◎Aluminium-alloy IP65 single point load cell;
◎Colourless anodized;
◎Suitable for single and double load cells structured platform scales;
◎Maximum platform size: 600 x 600 mm;
◎A 1000 Ohm type available (R1) but is excluded from OIML;
Dimensions in mm:
Available models:
Capacity | Accuracy | Full article description | Capacity | Accuracy | Full article description |
50kg | C3 | L6G-C3-50kg-3G6 | 250 kg | C3/C4 | L6G-C3/C4-250kg-3G6 |
100 kg | C3 | L6G-C3-100kg-3G6 | 300kg | C3/C4 | L6G-C3/C4-300kg-3G6 |
150kg | C3/C4 | L6G-C3/C4-150kg-3G6 | 500kg | C3/C4 | L6G-C3/C4-500kg-3G6 |
200kg | C3/C4 | L6G-C3/C4-200kg-3G6 | 600kg | C3/C4 | L6G-C3/C4-600kg-3G6 |
Specification:
Accuracy class | OIML R60 C3 | OIML R60 C4 | |
Output sensitivity(= FS) | mV/V | 2.0 ±0.2 | |
Maximum capacity (Emax) | kg | 50,100, 150,200, 250,300,500,600 | 150, 200, 250, 300, 500,600 |
Maximum number of load cell intervals (nLC) | 3000 | 4000 | |
Ratio of minimum LC verification interval Y = Emax / Vmin | 10000 | 15000 | |
Combined error | %FS | ± 0.02 | ±0.0150 |
Minimum dead load | kg | 0 | |
Safe overload | of Emax | 120% | |
UItimate overload | of Emax | 150% | |
Zero balance | %FS | ± 2.0 | |
Excitation, recommended voltage | V | 5~12(DC) | |
Excitation maximum | V | 18(DC) | |
Input resistance | Ω | 406 ±6 | |
Output resistance | Ω | 350±3 | |
Insulation resistance | MΩ | ≥ 5000(50VDC) | |
Compensated temperature | ℃ | -10~+40 | |
Operating temperature | ℃ | -35~+65 | |
Storage temperature | ℃ | -40~+70 | |
Element material | Aluminium | ||
Recommended torque on fixation | N.m | M8:25 | |
Ingress protection (according to EN 60529) | IP65 |
Wiring:
◎Shielded, 6 conductor cable;
◎Cable diameter: Φ5.9mm;
◎Cable length: 3m;
◎Shield connected to element;
◎Cable jacket in PVC;
Short Description:
◎Aluminium-alloy IP65 single point load cell;
◎Colourless anodized;
◎Suitable for single and double load cells structured platform scales;
◎Maximum platform size: 600 x 600 mm;
◎A 1000 Ohm type available (R1) but is excluded from OIML;
Dimensions in mm:
Available models:
Capacity | Accuracy | Full article description | Capacity | Accuracy | Full article description |
50kg | C3 | L6G-C3-50kg-3G6 | 250 kg | C3/C4 | L6G-C3/C4-250kg-3G6 |
100 kg | C3 | L6G-C3-100kg-3G6 | 300kg | C3/C4 | L6G-C3/C4-300kg-3G6 |
150kg | C3/C4 | L6G-C3/C4-150kg-3G6 | 500kg | C3/C4 | L6G-C3/C4-500kg-3G6 |
200kg | C3/C4 | L6G-C3/C4-200kg-3G6 | 600kg | C3/C4 | L6G-C3/C4-600kg-3G6 |
Specification:
Accuracy class | OIML R60 C3 | OIML R60 C4 | |
Output sensitivity(= FS) | mV/V | 2.0 ±0.2 | |
Maximum capacity (Emax) | kg | 50,100, 150,200, 250,300,500,600 | 150, 200, 250, 300, 500,600 |
Maximum number of load cell intervals (nLC) | 3000 | 4000 | |
Ratio of minimum LC verification interval Y = Emax / Vmin | 10000 | 15000 | |
Combined error | %FS | ± 0.02 | ±0.0150 |
Minimum dead load | kg | 0 | |
Safe overload | of Emax | 120% | |
UItimate overload | of Emax | 150% | |
Zero balance | %FS | ± 2.0 | |
Excitation, recommended voltage | V | 5~12(DC) | |
Excitation maximum | V | 18(DC) | |
Input resistance | Ω | 406 ±6 | |
Output resistance | Ω | 350±3 | |
Insulation resistance | MΩ | ≥ 5000(50VDC) | |
Compensated temperature | ℃ | -10~+40 | |
Operating temperature | ℃ | -35~+65 | |
Storage temperature | ℃ | -40~+70 | |
Element material | Aluminium | ||
Recommended torque on fixation | N.m | M8:25 | |
Ingress protection (according to EN 60529) | IP65 |
Wiring:
◎Shielded, 6 conductor cable;
◎Cable diameter: Φ5.9mm;
◎Cable length: 3m;
◎Shield connected to element;
◎Cable jacket in PVC;