Short Description:
◎Nickel plated alloy steel IP68 shear beam load cell;
◎Hermetically sealed;
◎Suitable for electronic platform scales, hopper scales;
◎High accuracy;
Dimensions in mm:
Dimension | 0.5t | 1t | 1.5t-2t | 2.5t | 3t-5t | 10t | ||||||
L | 130 | (5.12) | 130 | (5.12) | 130 | (5.12) | 171.5 | (6.75) | 171.5 | (6.75) | 222.3 | |
L1 | 15.8 | (0.62) | 15.8 | (0.62) | 15.8 | (0.62) | 19.1 | (0.75) | 19.1 | (0.75) | 25.4 | (1.00) |
L2 | 25.4 | (1.00) | 25.4 | (1.00) | 25.4 | (1.00) | 38.1 | (1.50) | 38.1 | (1.50) | 50.8 | (2.00) |
L3 | 76.2 | (3.00) | 76.2 | (3.00) | 76.2 | (3.00) | 95.3 | (3.75) | 95.3 | (3.75) | 120.3 | (4.74) |
L4 | 53.7 | (2.11) | 53.7 | (2.11) | 54.2 | (2.13) | 76.2 | (3.00) | 77.2 | (3.04) | 101.6 | (4.00) |
H | 31.8 | (1.25) | 31.8 | (1.25) | 31.8 | (1.25) | 38.1 | (1.50) | 38.1 | (1.50) | 50.8 | (2.00) |
H1 | 15.8 | (0.62) | 15.8 | (0.62) | 15.8 | (0.62) | 18.8 | (0.74) | 18.8 | (0.74) | 25.4 | (1.00) |
H2 | 26 | (1.02) | 28 | (1.10) | - | 34 | (1.34) | - | - | |||
B | 31.8 | (1.25) | 31.8 | (1.25) | 31.8 | (1.25) | 38.1 | (1.50) | 38.1 | (1.50) | 50.8 | (2.00) |
ΦD | 13.5 | (0.53) | 13.5 | (0.53) | 13.5 | (0.53) | 19.8 | (0.78) | 19.8 | (0.78) | 26 | (1.02) |
Φd | 13.5 | (0.53) | 13.5 | (0.53) | 13.5 | (0.53) | 19.8 | (0.78) | 19.8 | (0.78) | 26 | (1.02) |
M | M12 | M12 | M12 | M18 | M18 | M24 |
Available models:
Capacity | Accuracy | Full article description |
500kg | C3 Excluded from OIML | HM8C-C3-500kg-4B |
1t | C3 Excluded from OIML | HM8C-C3-1t-4B |
1.5t | C3 Excluded from OIML | HM8C-C3-1.5t-4B |
2t | C3 Excluded from OIML | HM8C-C3-2t-4B |
3t | C3 Excluded from OIML | HM8C-C3-3t-4B |
5t | C3 Excluded from OIML | HM8C-C3-5t-4B |
10t | C3 Excluded from OIML | HM8C-C3-10t-4B |
Specification:
Accuracy class | C3 | |||
Output sensitivity ( = FS ) | mV/V | 2.0 ± 0.004 | ||
Maximum capacity ( Emax ) | t | 0.5, 1, 1.5, 2, 3, 5, 10 | ||
Maximum number of load cell intervals ( nLC ) | 3000 | |||
Ratio of minimum LC verification interval Y = Emax / vmin | 10000 | |||
Combined error | %FS | ± 0.0230 | ||
Minimum dead load | of Emax | 0% | ||
Safe overload | of Emax | 150 % | ||
Ultimate overload | of Emax | 300 % | ||
Zero balance | %FS | ± 1.5 | ||
Excitation, recommended voltage | V | 5 ~ 12( DC ) | ||
Excitation maximum | V | 18( DC ) | ||
Input resistance | Ω | 350 ± 3.5 | ||
Output resistance | Ω | 351 ± 2.0 | ||
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) | ||
Compensated temperature | ℃ | -10 ~+40 | ||
Operating temperature | ℃ | -35 ~ +65 | ||
Storage temperature | ℃ | -40 ~ +70 | ||
Element material | Nickel plated alloy steel | |||
Ingress protection (acc. to EN 60529) | IP68 | |||
Recommended torque on fixation | N.m | M12: 100 M18:300 M24:750 | ||
ATEX classification (optional) | II1G Ex ia IIC T4 | II1D Ex iaD 20 T73℃ C | II3G Ex nL IIC T4 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable diameter: Φ5mm;
◎Standard cable length for 500kg -2t:4m and for 3t - 10t: 6m;
◎Shield not connected to element;
Short Description:
◎Nickel plated alloy steel IP68 shear beam load cell;
◎Hermetically sealed;
◎Suitable for electronic platform scales, hopper scales;
◎High accuracy;
Dimensions in mm:
Dimension | 0.5t | 1t | 1.5t-2t | 2.5t | 3t-5t | 10t | ||||||
L | 130 | (5.12) | 130 | (5.12) | 130 | (5.12) | 171.5 | (6.75) | 171.5 | (6.75) | 222.3 | |
L1 | 15.8 | (0.62) | 15.8 | (0.62) | 15.8 | (0.62) | 19.1 | (0.75) | 19.1 | (0.75) | 25.4 | (1.00) |
L2 | 25.4 | (1.00) | 25.4 | (1.00) | 25.4 | (1.00) | 38.1 | (1.50) | 38.1 | (1.50) | 50.8 | (2.00) |
L3 | 76.2 | (3.00) | 76.2 | (3.00) | 76.2 | (3.00) | 95.3 | (3.75) | 95.3 | (3.75) | 120.3 | (4.74) |
L4 | 53.7 | (2.11) | 53.7 | (2.11) | 54.2 | (2.13) | 76.2 | (3.00) | 77.2 | (3.04) | 101.6 | (4.00) |
H | 31.8 | (1.25) | 31.8 | (1.25) | 31.8 | (1.25) | 38.1 | (1.50) | 38.1 | (1.50) | 50.8 | (2.00) |
H1 | 15.8 | (0.62) | 15.8 | (0.62) | 15.8 | (0.62) | 18.8 | (0.74) | 18.8 | (0.74) | 25.4 | (1.00) |
H2 | 26 | (1.02) | 28 | (1.10) | - | 34 | (1.34) | - | - | |||
B | 31.8 | (1.25) | 31.8 | (1.25) | 31.8 | (1.25) | 38.1 | (1.50) | 38.1 | (1.50) | 50.8 | (2.00) |
ΦD | 13.5 | (0.53) | 13.5 | (0.53) | 13.5 | (0.53) | 19.8 | (0.78) | 19.8 | (0.78) | 26 | (1.02) |
Φd | 13.5 | (0.53) | 13.5 | (0.53) | 13.5 | (0.53) | 19.8 | (0.78) | 19.8 | (0.78) | 26 | (1.02) |
M | M12 | M12 | M12 | M18 | M18 | M24 |
Available models:
Capacity | Accuracy | Full article description |
500kg | C3 Excluded from OIML | HM8C-C3-500kg-4B |
1t | C3 Excluded from OIML | HM8C-C3-1t-4B |
1.5t | C3 Excluded from OIML | HM8C-C3-1.5t-4B |
2t | C3 Excluded from OIML | HM8C-C3-2t-4B |
3t | C3 Excluded from OIML | HM8C-C3-3t-4B |
5t | C3 Excluded from OIML | HM8C-C3-5t-4B |
10t | C3 Excluded from OIML | HM8C-C3-10t-4B |
Specification:
Accuracy class | C3 | |||
Output sensitivity ( = FS ) | mV/V | 2.0 ± 0.004 | ||
Maximum capacity ( Emax ) | t | 0.5, 1, 1.5, 2, 3, 5, 10 | ||
Maximum number of load cell intervals ( nLC ) | 3000 | |||
Ratio of minimum LC verification interval Y = Emax / vmin | 10000 | |||
Combined error | %FS | ± 0.0230 | ||
Minimum dead load | of Emax | 0% | ||
Safe overload | of Emax | 150 % | ||
Ultimate overload | of Emax | 300 % | ||
Zero balance | %FS | ± 1.5 | ||
Excitation, recommended voltage | V | 5 ~ 12( DC ) | ||
Excitation maximum | V | 18( DC ) | ||
Input resistance | Ω | 350 ± 3.5 | ||
Output resistance | Ω | 351 ± 2.0 | ||
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) | ||
Compensated temperature | ℃ | -10 ~+40 | ||
Operating temperature | ℃ | -35 ~ +65 | ||
Storage temperature | ℃ | -40 ~ +70 | ||
Element material | Nickel plated alloy steel | |||
Ingress protection (acc. to EN 60529) | IP68 | |||
Recommended torque on fixation | N.m | M12: 100 M18:300 M24:750 | ||
ATEX classification (optional) | II1G Ex ia IIC T4 | II1D Ex iaD 20 T73℃ C | II3G Ex nL IIC T4 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable diameter: Φ5mm;
◎Standard cable length for 500kg -2t:4m and for 3t - 10t: 6m;
◎Shield not connected to element;