HM2D4
SAINTBOND
Short Description:
◎Nickel plated alloy steel IP68 spoke type load cell;
◎Tension and compression applications;
◎Suitable for truck scales, hopper scales, automobile testing facilities and other electronic weighing or force measuring field;
Available models:
Capacity | Accuracy | Full article description |
0.5t~10t | C3 | HM2D4-C3-xxt-5B6 |
20t | G1 | HM2D4-G1-20t-5B6 |
50t | G3 | HM2D4-G3-50t-5B6 |
Specification:
Accuracy class | C3 | G1 | G3 | |
Maximum capacity ( Emax) | t | 0.5/1/2/3/5/10 | 20 | 50 |
Ratio of minimum LC verification interval Y= Emax / Vmin | Vmin | 7500 | ||
Combined error | %FS | 0.02 | 0.1 | 0.3 |
Creep | %FS/30min | ±0.016 | ±0.05 | ±0.1 |
Temperature effect on sensitivity | %FS/10℃ | ±0.011 | ±0.1 | ±0.2 |
Temperature effect on zero | %FS/10℃ | ±0.019 | ±0.1 | ±0.2 |
Output sensitivity (= FS) | mV/V | 2.0±0.002 | ||
Input resistance | Ω | 350±3.5 | ||
Output resistance | Ω | 350±3.5 | ||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||
Zero balance | %FS | 0-1.0 | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Safe overload | Of Emax | 150 | ||
UItimate overload | Of Emax | 300 |
Dimensions in mm:
Dimension(mm) Capacity(t) | D | D1 | H | M |
0.5t~2t | 105 (4.13) | 28 (1.10) | 70 (2.76) | M14×2 |
3t, 5t | 120 (4.72) | 33 (1.3) | 80 (3.15) | M20×1.5 |
10t, 20t | 155 (6.10) | 60.5 (2.38) | 90 (3.54) | M32×2 |
50t | 200 (7.87) | 75 (2.95) | 120 (4.72) | M45×3 |
Wiring:
◎Shielded, 6 conductor cable: Φ5.6mm;
◎Standard cable length: 5m;
Short Description:
◎Nickel plated alloy steel IP68 spoke type load cell;
◎Tension and compression applications;
◎Suitable for truck scales, hopper scales, automobile testing facilities and other electronic weighing or force measuring field;
Available models:
Capacity | Accuracy | Full article description |
0.5t~10t | C3 | HM2D4-C3-xxt-5B6 |
20t | G1 | HM2D4-G1-20t-5B6 |
50t | G3 | HM2D4-G3-50t-5B6 |
Specification:
Accuracy class | C3 | G1 | G3 | |
Maximum capacity ( Emax) | t | 0.5/1/2/3/5/10 | 20 | 50 |
Ratio of minimum LC verification interval Y= Emax / Vmin | Vmin | 7500 | ||
Combined error | %FS | 0.02 | 0.1 | 0.3 |
Creep | %FS/30min | ±0.016 | ±0.05 | ±0.1 |
Temperature effect on sensitivity | %FS/10℃ | ±0.011 | ±0.1 | ±0.2 |
Temperature effect on zero | %FS/10℃ | ±0.019 | ±0.1 | ±0.2 |
Output sensitivity (= FS) | mV/V | 2.0±0.002 | ||
Input resistance | Ω | 350±3.5 | ||
Output resistance | Ω | 350±3.5 | ||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||
Zero balance | %FS | 0-1.0 | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Safe overload | Of Emax | 150 | ||
UItimate overload | Of Emax | 300 |
Dimensions in mm:
Dimension(mm) Capacity(t) | D | D1 | H | M |
0.5t~2t | 105 (4.13) | 28 (1.10) | 70 (2.76) | M14×2 |
3t, 5t | 120 (4.72) | 33 (1.3) | 80 (3.15) | M20×1.5 |
10t, 20t | 155 (6.10) | 60.5 (2.38) | 90 (3.54) | M32×2 |
50t | 200 (7.87) | 75 (2.95) | 120 (4.72) | M45×3 |
Wiring:
◎Shielded, 6 conductor cable: Φ5.6mm;
◎Standard cable length: 5m;