H9D
SAINTBOND
Short Description:
◎Nickel plated alloy steel IP67 dual shear beam load cell;
◎High accuracy;
◎Suitable for truck and track scales and other heavy weighing devices;
◎Sealed construction;
Dimensions in mm:
Dimension Capacity | L | L1 | L2 | H | h | B | ΦD | Φd |
1Klb-5Klb | 190.5 | 158.75 | 15.9 | 30.99 | 16.76 | 30.99 | 31.5 | 12.7 |
(7.50) | (6.25) | (0.63) | (1.22) | (0.66) | (1.22) | (1.24) | (0.50) | |
10Klb-35Klb | 222.25 | 190.5 | 15.9 | 49.15 | 24.58 | 36.45 | 50.8 | 20.57 |
(8.75) | (7.50) | (0.63) | (1.94) | (12.67) | (1.44) | (2.00) | (0.81) | |
50Klb-75Klb | 342.9 | 292.1 | 25.4 | 74.68 | 37.37 | 61.98 | 75.95 | 33.32 |
(13.50) | (11.50) | (1.00) | (2.94) | (1.47) | (2.44) | (2.99) | (1.31) |
Available models:
Capacity | Accuracy | Full article description | Capacity | Accuracy | Full article description |
1Klb | N3 | H9D-N3-1K-6B | 15 Klb | N3 | H9D-N3-15K-6B |
1.5Klb | N3 | H9D-N3-1.5K-6B | 20 Klb | C3/C4/C5 | H9D-C3/C4/C5-20K-6B |
2Klb | N3 | H9D-N3-2K-6B | 25 Klb | C3/C4/C5 | H9D-C3/C4/C5-25K-6B |
2.5Klb | N3 | H9D-N3-2.5K-6B | 35 Klb | C3/C4/C5 | H9D-C3/C4/C5-35K-6B |
4Klb | N3 | H9D-N3-4K-6B | 50 Klb | C3/C4/C5 | H9D-C3/C4/C5-50K-6B |
5Klb | N3 | H9D-N3-5K-6B | 75 Klb | C3/C4/C5 | H9D-C3/C4/C5-75K-6B |
10Klb | N3 | H9D-N3-10K-6B |
Specification:
Accuracy class | N3 | OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | |
Output sensitivity ( = FS ) | mV/V | 3.0 ± 0.008 | |||
Maximum capacity ( Emax ) | klb | 1,1.5,2,2.5,4,5,10,15 | 20,25,35,50,75 | ||
Maximum number of load cell intervals ( nLC ) | 3000 | 4000 | 5000 | ||
Ratio of minimum LC verification interval Y = Emax / vmin | 10000 | 15000 | 20000 | ||
Combined error | %FS | ± 0.023 | ± 0.0175 | ± 0.0140 | |
Minimum dead load | of Emax | 0 % | |||
Safe overload | of Emax | 150 % | |||
Ultimate overload | of Emax | 300 % | |||
Zero balance | %FS | ± 1.0 | |||
Excitation, recommended voltage | V | 5 ~ 12( DC ) | |||
Excitation maximum | V | 18( DC ) | |||
Input resistance | Ω | 700 ± 7 | |||
Output resistance | Ω | 703 ± 4 | |||
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) | |||
Compensated temperature | ℃ | -10 ~+40 | |||
Operating temperature | ℃ | -35 ~ +65 | |||
Storage temperature | ℃ | -40 ~ +70 | |||
Element material | Nickel plated alloy steel | ||||
Ingress protection (according to EN 60529) | IP67 | ||||
ATEX classification (optional) | II1G Ex ia IIC T4 | II1D Ex iaD 20 T73℃ C | II3G Ex nL IIC T4 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable diameter: Φ5mm;
◎Standard cable length: 6m;
◎Shield not connected to element;
Short Description:
◎Nickel plated alloy steel IP67 dual shear beam load cell;
◎High accuracy;
◎Suitable for truck and track scales and other heavy weighing devices;
◎Sealed construction;
Dimensions in mm:
Dimension Capacity | L | L1 | L2 | H | h | B | ΦD | Φd |
1Klb-5Klb | 190.5 | 158.75 | 15.9 | 30.99 | 16.76 | 30.99 | 31.5 | 12.7 |
(7.50) | (6.25) | (0.63) | (1.22) | (0.66) | (1.22) | (1.24) | (0.50) | |
10Klb-35Klb | 222.25 | 190.5 | 15.9 | 49.15 | 24.58 | 36.45 | 50.8 | 20.57 |
(8.75) | (7.50) | (0.63) | (1.94) | (12.67) | (1.44) | (2.00) | (0.81) | |
50Klb-75Klb | 342.9 | 292.1 | 25.4 | 74.68 | 37.37 | 61.98 | 75.95 | 33.32 |
(13.50) | (11.50) | (1.00) | (2.94) | (1.47) | (2.44) | (2.99) | (1.31) |
Available models:
Capacity | Accuracy | Full article description | Capacity | Accuracy | Full article description |
1Klb | N3 | H9D-N3-1K-6B | 15 Klb | N3 | H9D-N3-15K-6B |
1.5Klb | N3 | H9D-N3-1.5K-6B | 20 Klb | C3/C4/C5 | H9D-C3/C4/C5-20K-6B |
2Klb | N3 | H9D-N3-2K-6B | 25 Klb | C3/C4/C5 | H9D-C3/C4/C5-25K-6B |
2.5Klb | N3 | H9D-N3-2.5K-6B | 35 Klb | C3/C4/C5 | H9D-C3/C4/C5-35K-6B |
4Klb | N3 | H9D-N3-4K-6B | 50 Klb | C3/C4/C5 | H9D-C3/C4/C5-50K-6B |
5Klb | N3 | H9D-N3-5K-6B | 75 Klb | C3/C4/C5 | H9D-C3/C4/C5-75K-6B |
10Klb | N3 | H9D-N3-10K-6B |
Specification:
Accuracy class | N3 | OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | |
Output sensitivity ( = FS ) | mV/V | 3.0 ± 0.008 | |||
Maximum capacity ( Emax ) | klb | 1,1.5,2,2.5,4,5,10,15 | 20,25,35,50,75 | ||
Maximum number of load cell intervals ( nLC ) | 3000 | 4000 | 5000 | ||
Ratio of minimum LC verification interval Y = Emax / vmin | 10000 | 15000 | 20000 | ||
Combined error | %FS | ± 0.023 | ± 0.0175 | ± 0.0140 | |
Minimum dead load | of Emax | 0 % | |||
Safe overload | of Emax | 150 % | |||
Ultimate overload | of Emax | 300 % | |||
Zero balance | %FS | ± 1.0 | |||
Excitation, recommended voltage | V | 5 ~ 12( DC ) | |||
Excitation maximum | V | 18( DC ) | |||
Input resistance | Ω | 700 ± 7 | |||
Output resistance | Ω | 703 ± 4 | |||
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) | |||
Compensated temperature | ℃ | -10 ~+40 | |||
Operating temperature | ℃ | -35 ~ +65 | |||
Storage temperature | ℃ | -40 ~ +70 | |||
Element material | Nickel plated alloy steel | ||||
Ingress protection (according to EN 60529) | IP67 | ||||
ATEX classification (optional) | II1G Ex ia IIC T4 | II1D Ex iaD 20 T73℃ C | II3G Ex nL IIC T4 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable diameter: Φ5mm;
◎Standard cable length: 6m;
◎Shield not connected to element;