BM8D
SAINTBOND
Short Description:
◎Stainless steel shear beam load cell (150kg and 300 kg are bending beam load cells);
◎Hermetically sealed IP68;
◎Suitable for floor scales, vehicle-test line, hopper scales and other electronic weighing devices;
◎High accuracy;
◎Wide range of capacities;
Dimensions in mm:
Dimension | L | L1 | L2 | L3 | L4 | B | H | h | ΦD | ΦD1 | Φd1 | Φd2 | M |
0.15t-0.3t | 130 | 15.7 | 25.4 | 76.2 | 57.1 | 31.3 | 31.3 | - | 13.5 | 18 | 4 | 2 | M12 |
0.5t | 31.1 | 24.8 | |||||||||||
1t | 313 | 26.0 | |||||||||||
1.5t-2t | 28 | ||||||||||||
2.5t- 5t | 171 | 19 | 38.1 | 95.2 | 76.2 | 36.8 | 34.8 | 20.5 | 25 | 4 | 2 | M20 | |
7.5t-10T | 222 | 25.4 | 50.8 | 120.7 | 101.6 | 49.5 | 49.5 | 47.5 | 26.9 | - | - | - | M24 |
Available models:
Capacity | Accuracy | Full article description |
xxkg | C3/C5/C6/A5M/B10S/B10M | BM8D-xx-xxkg-6B |
xxt | C3/C5/C6/A5M/B10S/B10M | BM8D-xx-xxt-6B |
xxib | A5M/B10S/B10M | BM8D-xx-xx-6YB |
xxklb | A5M/B10S/B10M | BM8D-xx-xxK-6YB |
◎50kg-300kg approved by OIML C3;◎3.0t-15t approved by OIML C5;◎500kg-2.5t approved by OIML C6; |
Specification:
Accuracy class | OIML R6O C3 | OIML R60 C4 | OIML R60 C5 | OIML R60 C6 | |
Output sensitivi(= FS) | mVN | 2.0± 0.0043.0 +0.008 | |||
Maximum capacity ( Emax) | t | 0.15,0.3,0.5,1,1.5,2,2.5,3,5,7.5,10 | 0.5,1,1.5,2,2.5 | ||
Maximum number of load cell intervals (nLC) | N.max | 3000 | 4000 | 5000 | 6000 |
Ratio of minimum LC verification interval Y = Emax / Vmin | Y | 10000 | 15000 | 20000 | 20000 |
Combinederror | %FS | ± 0.0230 | ± 0.0175 | ±0.0140 | ± 0.0116 |
Minimum dead load | of Emax | 0% | |||
Safe overload | of Emax | 150% | |||
Uitimate overload | of Emax | 300% | |||
Zero balance | %FS | ± 1.0 | |||
Excitation, recommended voltage | V | 5~12(DC) | |||
Excitation maximum | V | 18(DC) | |||
Input resistance | Ω | 350 ±3.5 | |||
Output resistance0) | Ω | 350 ±3.5 | |||
Insulation resistance | MΩ | ≥ 5000(50VDC) | |||
Compensated temperature | ℃ | -10~+40 | |||
Operating temperature | ℃ | -35~+65 | |||
Storagetemperature | ℃ | -40~+70 | |||
Element material | Stainless steel | ||||
Recommended torque on fixation | N.m | M12:75 M20:450 M24:750 | |||
lngress protection (according to EN 60529) | IP68 | ||||
ATEX classification (optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD 20 T73℃ | Ⅱ3G Ex nL ⅡC T4 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable Diameter: Φ5mm;
◎Standard cable length: 5m;
◎Shield not connected to element;
Short Description:
◎Stainless steel shear beam load cell (150kg and 300 kg are bending beam load cells);
◎Hermetically sealed IP68;
◎Suitable for floor scales, vehicle-test line, hopper scales and other electronic weighing devices;
◎High accuracy;
◎Wide range of capacities;
Dimensions in mm:
Dimension | L | L1 | L2 | L3 | L4 | B | H | h | ΦD | ΦD1 | Φd1 | Φd2 | M |
0.15t-0.3t | 130 | 15.7 | 25.4 | 76.2 | 57.1 | 31.3 | 31.3 | - | 13.5 | 18 | 4 | 2 | M12 |
0.5t | 31.1 | 24.8 | |||||||||||
1t | 313 | 26.0 | |||||||||||
1.5t-2t | 28 | ||||||||||||
2.5t- 5t | 171 | 19 | 38.1 | 95.2 | 76.2 | 36.8 | 34.8 | 20.5 | 25 | 4 | 2 | M20 | |
7.5t-10T | 222 | 25.4 | 50.8 | 120.7 | 101.6 | 49.5 | 49.5 | 47.5 | 26.9 | - | - | - | M24 |
Available models:
Capacity | Accuracy | Full article description |
xxkg | C3/C5/C6/A5M/B10S/B10M | BM8D-xx-xxkg-6B |
xxt | C3/C5/C6/A5M/B10S/B10M | BM8D-xx-xxt-6B |
xxib | A5M/B10S/B10M | BM8D-xx-xx-6YB |
xxklb | A5M/B10S/B10M | BM8D-xx-xxK-6YB |
◎50kg-300kg approved by OIML C3;◎3.0t-15t approved by OIML C5;◎500kg-2.5t approved by OIML C6; |
Specification:
Accuracy class | OIML R6O C3 | OIML R60 C4 | OIML R60 C5 | OIML R60 C6 | |
Output sensitivi(= FS) | mVN | 2.0± 0.0043.0 +0.008 | |||
Maximum capacity ( Emax) | t | 0.15,0.3,0.5,1,1.5,2,2.5,3,5,7.5,10 | 0.5,1,1.5,2,2.5 | ||
Maximum number of load cell intervals (nLC) | N.max | 3000 | 4000 | 5000 | 6000 |
Ratio of minimum LC verification interval Y = Emax / Vmin | Y | 10000 | 15000 | 20000 | 20000 |
Combinederror | %FS | ± 0.0230 | ± 0.0175 | ±0.0140 | ± 0.0116 |
Minimum dead load | of Emax | 0% | |||
Safe overload | of Emax | 150% | |||
Uitimate overload | of Emax | 300% | |||
Zero balance | %FS | ± 1.0 | |||
Excitation, recommended voltage | V | 5~12(DC) | |||
Excitation maximum | V | 18(DC) | |||
Input resistance | Ω | 350 ±3.5 | |||
Output resistance0) | Ω | 350 ±3.5 | |||
Insulation resistance | MΩ | ≥ 5000(50VDC) | |||
Compensated temperature | ℃ | -10~+40 | |||
Operating temperature | ℃ | -35~+65 | |||
Storagetemperature | ℃ | -40~+70 | |||
Element material | Stainless steel | ||||
Recommended torque on fixation | N.m | M12:75 M20:450 M24:750 | |||
lngress protection (according to EN 60529) | IP68 | ||||
ATEX classification (optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD 20 T73℃ | Ⅱ3G Ex nL ⅡC T4 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable Diameter: Φ5mm;
◎Standard cable length: 5m;
◎Shield not connected to element;