Availability: | |
---|---|
Quantity: | |
BM6E
SAINTBOND
Short Description:
◎Stainless steel IP68 single point load cell;
◎Suitable for single load cell structured platform scales;
◎ High accuracy;
◎Maximum platform size: 600 x 600 mm;
Available models:
Capacity | Accuracy | Full article description |
50kg | C3 | BM6E-C3-50kg-2B |
100kg | C3 | BM6E-C3-100kg-2B |
150kg | C3 | BM6E-C3-150kg-2B |
200kg | C3 | BM6E-C3-200kg-2B |
250kg | C3 | BM6E-C3-250kg-2B |
300kg | C3 | BM6E-C3-300kg-2B |
Specification:
Accuracy class | C3 | |
Output sensitivity(= FS) | mV/V | 2.0±0.2 |
Maximum capacity (Emax) | kg | 50,100,150,200,250,300 |
Maximum number of load cell intervals (nLC) | 3000 | |
Ratio of minimum LC verification interval Y = Emax / Vmin | 10000 | |
Combined error | %FS | ±0.0230 |
Minimum dead load | of Emax | 0% |
Safe overload | of Emax | 150% |
Ultimate overload | of Emax | 300% |
Zero balance | %FS | ± 1.5 |
Excitation, recommended voltage | V | 5~12(DC) |
Excitation maximum | V | 18(DC) |
Input resistance | Ω | 350±3.5 |
Output resistance | Ω | 351±2.0 |
Insulation resistance | MΩ | ≥ 5000(50VDC) |
Compensated temperature | ℃ | -10~+40 |
Operating temperature | ℃ | -35~+65 |
Storage temperature | ℃ | -40~+70 |
Element material | Stainless steel | |
Recommended torque on fixation | N.m | M6:10 |
Corer correction | 0.02 % load value /100 mm | |
lngress protection (according to EN 60529) | IP68 | |
Note: "S1" output sensitivity is 2.0± 0.002mV/V |
Dimensions in mm:
Wiring:
◎Shielded cable, 4 conductor cable;
◎ Cable diameter: Φ5mm;
◎Standard cable length: 2m;
◎Shield not connected to element;
Short Description:
◎Stainless steel IP68 single point load cell;
◎Suitable for single load cell structured platform scales;
◎ High accuracy;
◎Maximum platform size: 600 x 600 mm;
Available models:
Capacity | Accuracy | Full article description |
50kg | C3 | BM6E-C3-50kg-2B |
100kg | C3 | BM6E-C3-100kg-2B |
150kg | C3 | BM6E-C3-150kg-2B |
200kg | C3 | BM6E-C3-200kg-2B |
250kg | C3 | BM6E-C3-250kg-2B |
300kg | C3 | BM6E-C3-300kg-2B |
Specification:
Accuracy class | C3 | |
Output sensitivity(= FS) | mV/V | 2.0±0.2 |
Maximum capacity (Emax) | kg | 50,100,150,200,250,300 |
Maximum number of load cell intervals (nLC) | 3000 | |
Ratio of minimum LC verification interval Y = Emax / Vmin | 10000 | |
Combined error | %FS | ±0.0230 |
Minimum dead load | of Emax | 0% |
Safe overload | of Emax | 150% |
Ultimate overload | of Emax | 300% |
Zero balance | %FS | ± 1.5 |
Excitation, recommended voltage | V | 5~12(DC) |
Excitation maximum | V | 18(DC) |
Input resistance | Ω | 350±3.5 |
Output resistance | Ω | 351±2.0 |
Insulation resistance | MΩ | ≥ 5000(50VDC) |
Compensated temperature | ℃ | -10~+40 |
Operating temperature | ℃ | -35~+65 |
Storage temperature | ℃ | -40~+70 |
Element material | Stainless steel | |
Recommended torque on fixation | N.m | M6:10 |
Corer correction | 0.02 % load value /100 mm | |
lngress protection (according to EN 60529) | IP68 | |
Note: "S1" output sensitivity is 2.0± 0.002mV/V |
Dimensions in mm:
Wiring:
◎Shielded cable, 4 conductor cable;
◎ Cable diameter: Φ5mm;
◎Standard cable length: 2m;
◎Shield not connected to element;