BM24R
SAINTBOND
Short Description:
◎Stainless steel IP68 low profile load cell;
◎Hermetically sealed;
◎Suitable for hopper, platform and pallet scales;
◎Integrated static overload protection up to 13t;
Available models:
Capacity | Accuracy | Full article description |
60kg | C3/C4/C5 | BM24R -60kg -C3/C4/C5 -3B |
130kg | C3/C4/C5 | BM24R -130kg -C3/C4/C5 -3B |
280kg | C3/C4/C5 | BM24R -280kg -C3/C4/C5 -3B |
250kg | C3/C4/C5 | BM24R -250kg -C3/C4/C5 -3B |
500kg | C3/C4/C5 | BM24R -500kg -C3/C4/C5 -3B |
1t | C3/C4/C5 | BM24R -1t -C3/C4/C5 -3B |
2t | C3/C4/C5 | BM24R-2t -C3/C4/C5 -6B |
3.5t | C3/C4/C5 | BM24R-3.5t -C3/C4/C5 -6B |
5t | C3/C4/C5 | BM24R-5t -C3/C4/C5 -6B |
10t | C3/C4/C5 | BM24R-10t -C3/C4/C5 -15B |
13t | C3/C4/C5 | BM24R-13t -C3/C4/C5 -15B |
28t | C3/C4/C5 | BM24R-28t -C3/C4/C5 -15B |
60t | C3/C4/C5 | BM24R-60t -C3/C4/C5 -15B |
Specification:
Accuracy class | OIML R60 C3 / OIML R60 C4 / OIML R60 C5 | ||||||
Output sensitivity ( = FS ) | mV/V | 1.0 ± 0.01 | 1.75±0.1 | 2.0 ± 0.1 | 2.0 ±0.1 | 2.0 ±0.1 | 2.0 ±0.1 |
Maximum capacity ( Emax ) | t | 0.06,0.13,0.28 | 0.25 | 0.5,1,2,3.5,5,10 | 13 | 28 | 60 |
Maximum number of load cell intervals ( nLC ) | C3 = 3000, C4 = 4000, C5 = 5000 | ||||||
Ratio of minimum LC verification interval Y = Emax / vmin | C3 = 10.000, C4 and C5 = 16.000 | ||||||
Combined error | %FS | C3 = ± 0.0230, C4 = ± 0.0174, C5 = ± 0.0140 | |||||
Minimum dead load | of Emax | 0 | |||||
Safe overload | of Emax | 150 % | |||||
Safe sideload | of Emax | 75% | |||||
Zero balance | %FS | ± 1.0 | |||||
Excitation, recommended voltage | V | 10 ~ 15(DC) | |||||
Excitation maximum | V | 30(DC) | |||||
Input resistance | Ω | 1260 ±100 | 1100±100 | 1100 ±100 | 1200±100 | 1075±100 | 1350±200 |
Output resistance | Ω | 1020 ±0.5 | 1025±25 | 1025 ±25 | 1000±0.5 | 930 ±0.5 | 1175±0.5 |
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) | |||||
Compensated temperature | ℃ | -10 ~+40 | |||||
Operating temperature | ℃ | -35 ~ +65 | |||||
Temperature range, storage | ℃ | -40 ~ +70 | |||||
Element material | Stainless steel | ||||||
Ingress protection (according to EN 60529) | IP68 | ||||||
Recommended torque on fixation | N.m | M5: 3.5 M6:10 |
Dimensions in mm:
Dimension | ΦA | ΦB | C | D | E | ΦF | G | H | I | J | ΦK | SR |
60kg / 130kg/ 280kg | 63 | 15.1 | 22 | 11 | 60 | 54 | 6 | 10 | Φ3.2 | -- | -- | -- |
0.25t/0.5t/1t | 80 | 19 | 26 | 12.5 | 65 | 71 | 10 | 18 | M10 | 1 | 25 | -- |
2t / 3.5t | 80 | 19 | 30 | 12.5 | 65 | 71 | 10 | 18 | Φ15 | 6 | 25 | -- |
10t | 95 | 26 | 35 | 12.5 | 72 | 75 | 20.7 | 31.2 | -- | -- | 29 | -- |
13t | 95 | 26 | 35 | 20 | 85 | 79.5 | 20 | 31 | -- | -- | 29 | -- |
28t | 120 | 35.9 | 46 | 25 | 94 | 102 | -- | 53 | -- | -- | -- | 400 |
60t | 140 | 47.9 | 62 | 34 | 104 | 124 | -- | 69 | -- | -- | -- | 600 |
Wiring:
◎Adopt shielded, 4 conductor cable: Φ6.2±0.1mm;
Capacity | Standard cable length(m) |
60Kg/130Kg/250Kg/280Kg/500Kg/1t | 3 |
2t/3.5t5t | 6 |
10t/13t/28t/60t | 15 |
Short Description:
◎Stainless steel IP68 low profile load cell;
◎Hermetically sealed;
◎Suitable for hopper, platform and pallet scales;
◎Integrated static overload protection up to 13t;
Available models:
Capacity | Accuracy | Full article description |
60kg | C3/C4/C5 | BM24R -60kg -C3/C4/C5 -3B |
130kg | C3/C4/C5 | BM24R -130kg -C3/C4/C5 -3B |
280kg | C3/C4/C5 | BM24R -280kg -C3/C4/C5 -3B |
250kg | C3/C4/C5 | BM24R -250kg -C3/C4/C5 -3B |
500kg | C3/C4/C5 | BM24R -500kg -C3/C4/C5 -3B |
1t | C3/C4/C5 | BM24R -1t -C3/C4/C5 -3B |
2t | C3/C4/C5 | BM24R-2t -C3/C4/C5 -6B |
3.5t | C3/C4/C5 | BM24R-3.5t -C3/C4/C5 -6B |
5t | C3/C4/C5 | BM24R-5t -C3/C4/C5 -6B |
10t | C3/C4/C5 | BM24R-10t -C3/C4/C5 -15B |
13t | C3/C4/C5 | BM24R-13t -C3/C4/C5 -15B |
28t | C3/C4/C5 | BM24R-28t -C3/C4/C5 -15B |
60t | C3/C4/C5 | BM24R-60t -C3/C4/C5 -15B |
Specification:
Accuracy class | OIML R60 C3 / OIML R60 C4 / OIML R60 C5 | ||||||
Output sensitivity ( = FS ) | mV/V | 1.0 ± 0.01 | 1.75±0.1 | 2.0 ± 0.1 | 2.0 ±0.1 | 2.0 ±0.1 | 2.0 ±0.1 |
Maximum capacity ( Emax ) | t | 0.06,0.13,0.28 | 0.25 | 0.5,1,2,3.5,5,10 | 13 | 28 | 60 |
Maximum number of load cell intervals ( nLC ) | C3 = 3000, C4 = 4000, C5 = 5000 | ||||||
Ratio of minimum LC verification interval Y = Emax / vmin | C3 = 10.000, C4 and C5 = 16.000 | ||||||
Combined error | %FS | C3 = ± 0.0230, C4 = ± 0.0174, C5 = ± 0.0140 | |||||
Minimum dead load | of Emax | 0 | |||||
Safe overload | of Emax | 150 % | |||||
Safe sideload | of Emax | 75% | |||||
Zero balance | %FS | ± 1.0 | |||||
Excitation, recommended voltage | V | 10 ~ 15(DC) | |||||
Excitation maximum | V | 30(DC) | |||||
Input resistance | Ω | 1260 ±100 | 1100±100 | 1100 ±100 | 1200±100 | 1075±100 | 1350±200 |
Output resistance | Ω | 1020 ±0.5 | 1025±25 | 1025 ±25 | 1000±0.5 | 930 ±0.5 | 1175±0.5 |
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) | |||||
Compensated temperature | ℃ | -10 ~+40 | |||||
Operating temperature | ℃ | -35 ~ +65 | |||||
Temperature range, storage | ℃ | -40 ~ +70 | |||||
Element material | Stainless steel | ||||||
Ingress protection (according to EN 60529) | IP68 | ||||||
Recommended torque on fixation | N.m | M5: 3.5 M6:10 |
Dimensions in mm:
Dimension | ΦA | ΦB | C | D | E | ΦF | G | H | I | J | ΦK | SR |
60kg / 130kg/ 280kg | 63 | 15.1 | 22 | 11 | 60 | 54 | 6 | 10 | Φ3.2 | -- | -- | -- |
0.25t/0.5t/1t | 80 | 19 | 26 | 12.5 | 65 | 71 | 10 | 18 | M10 | 1 | 25 | -- |
2t / 3.5t | 80 | 19 | 30 | 12.5 | 65 | 71 | 10 | 18 | Φ15 | 6 | 25 | -- |
10t | 95 | 26 | 35 | 12.5 | 72 | 75 | 20.7 | 31.2 | -- | -- | 29 | -- |
13t | 95 | 26 | 35 | 20 | 85 | 79.5 | 20 | 31 | -- | -- | 29 | -- |
28t | 120 | 35.9 | 46 | 25 | 94 | 102 | -- | 53 | -- | -- | -- | 400 |
60t | 140 | 47.9 | 62 | 34 | 104 | 124 | -- | 69 | -- | -- | -- | 600 |
Wiring:
◎Adopt shielded, 4 conductor cable: Φ6.2±0.1mm;
Capacity | Standard cable length(m) |
60Kg/130Kg/250Kg/280Kg/500Kg/1t | 3 |
2t/3.5t5t | 6 |
10t/13t/28t/60t | 15 |