B8D
SAINTBOND
Short Description:
◎Stainless steel IP67 shear beam load cell (250kg is bending beam load cells);
◎Suitable for floor scales, automobile test facilities,hopper scales and other weighing devices;
◎Current calibrated (sc-option);
Dimensions in mm:
Dimension Capacity | L | L1 | L2 | L3 | d | H | W | D | H1 | M |
0.25t | 130 (5.12) | 15.7 (0.62) | 25.4 (1.0) | 76.2 (3.0) | 13.46 (0.53) | 28.4 (1.12) | 30.7 (1.20) | 13.4 (0.53) | 14.22 (0.56) | M12 |
0.5t-2t | 130 (5.12) | 15.7 (0.62) | 25.4 (1.0) | 76.2 (3.0) | 13.46 (0.53) | 31.32 (1.23) | 31.32 (1.23) | 13.4 (0.53) | 15.75 (0.62) | M12 |
5t | 171 (6.73) | 19 (0.75) | 38.1 (1.5) | 95.2 (3.75) | 20.65 | 36.8 (1.45) | 36.8 (1.45) | 20.65 | 19.05 (0.75) | M20*2.5 |
Available models:
Capacity | Accuracy | Full article description |
250kg | C3/C4/C5 | B8D-C3/C4/C5-250kg-6B(-W6) |
0.5t | C3/C4/C5 | B8D-C3/C4/C5-500kg-6B(-W6) |
1t | C3 | B8D-C3-1t-6B(-W6) |
2t | C3 | B8D-C3-2t-6B(-W6) |
5t | C3 | B8D-C3-5t-6B(-W6) |
Specification:
Accuracy class | OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | |||
Output sensitivity(= FS) | mV/V | 3.0 ±0.008 | ||||
Maximum capacity ( Emax) | t | 0.25 | 0.5,1,2 | 5 | 0.25,0.5 | |
Maximum number of load cell intervals (nLC) | 3000 | 4000 | 5000 | |||
Ratio of minimum LC verification interval Y = Emax / Vmin() | 10000 | 7500 | 9000 | 10000 | 10000 | |
Combined error | %FS | ± 0.0230 | ±0.0175 | ±0.0140 | ||
Safe overload | of Emax | 150% | ||||
Ultimate overload | of Emax | 300% | ||||
Zero balance | %FS | ±1.0 | ||||
Excitation, recommended voltage | V | 5~12(DC) | ||||
Excitation maximum | V | 18(DC) | ||||
lnput resistance | Ω | 350±3.5 | ||||
Output resistance | Ω | 350 ±3.5 | ||||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||||
Compensated temperature | ℃ | -10~+40 | ||||
Operating temperature | ℃ | -35~+65 | ||||
Storage temperature | ℃ | -40~+70 | ||||
Element material | Stainless steel | |||||
Recommended torque on fixation | N.m | M12:75 M20:450 | ||||
Ingress protection (according to EN 60529) | IP67 | |||||
ATEX classification (optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD 20 T73℃ | Ⅱ3G Ex nL ⅡC T4 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable Diameter: Φ5mm;
◎Standard cable length: 6m;
◎Shield not connected to element;
Short Description:
◎Stainless steel IP67 shear beam load cell (250kg is bending beam load cells);
◎Suitable for floor scales, automobile test facilities,hopper scales and other weighing devices;
◎Current calibrated (sc-option);
Dimensions in mm:
Dimension Capacity | L | L1 | L2 | L3 | d | H | W | D | H1 | M |
0.25t | 130 (5.12) | 15.7 (0.62) | 25.4 (1.0) | 76.2 (3.0) | 13.46 (0.53) | 28.4 (1.12) | 30.7 (1.20) | 13.4 (0.53) | 14.22 (0.56) | M12 |
0.5t-2t | 130 (5.12) | 15.7 (0.62) | 25.4 (1.0) | 76.2 (3.0) | 13.46 (0.53) | 31.32 (1.23) | 31.32 (1.23) | 13.4 (0.53) | 15.75 (0.62) | M12 |
5t | 171 (6.73) | 19 (0.75) | 38.1 (1.5) | 95.2 (3.75) | 20.65 | 36.8 (1.45) | 36.8 (1.45) | 20.65 | 19.05 (0.75) | M20*2.5 |
Available models:
Capacity | Accuracy | Full article description |
250kg | C3/C4/C5 | B8D-C3/C4/C5-250kg-6B(-W6) |
0.5t | C3/C4/C5 | B8D-C3/C4/C5-500kg-6B(-W6) |
1t | C3 | B8D-C3-1t-6B(-W6) |
2t | C3 | B8D-C3-2t-6B(-W6) |
5t | C3 | B8D-C3-5t-6B(-W6) |
Specification:
Accuracy class | OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | |||
Output sensitivity(= FS) | mV/V | 3.0 ±0.008 | ||||
Maximum capacity ( Emax) | t | 0.25 | 0.5,1,2 | 5 | 0.25,0.5 | |
Maximum number of load cell intervals (nLC) | 3000 | 4000 | 5000 | |||
Ratio of minimum LC verification interval Y = Emax / Vmin() | 10000 | 7500 | 9000 | 10000 | 10000 | |
Combined error | %FS | ± 0.0230 | ±0.0175 | ±0.0140 | ||
Safe overload | of Emax | 150% | ||||
Ultimate overload | of Emax | 300% | ||||
Zero balance | %FS | ±1.0 | ||||
Excitation, recommended voltage | V | 5~12(DC) | ||||
Excitation maximum | V | 18(DC) | ||||
lnput resistance | Ω | 350±3.5 | ||||
Output resistance | Ω | 350 ±3.5 | ||||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||||
Compensated temperature | ℃ | -10~+40 | ||||
Operating temperature | ℃ | -35~+65 | ||||
Storage temperature | ℃ | -40~+70 | ||||
Element material | Stainless steel | |||||
Recommended torque on fixation | N.m | M12:75 M20:450 | ||||
Ingress protection (according to EN 60529) | IP67 | |||||
ATEX classification (optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD 20 T73℃ | Ⅱ3G Ex nL ⅡC T4 |
Wiring:
◎Shielded, 4 conductor cable;
◎Cable Diameter: Φ5mm;
◎Standard cable length: 6m;
◎Shield not connected to element;