Availability: | |
---|---|
Quantity: | |
B6G5 H6G5
SAINTBOND
Short Description:
◎Stainless/ alloy steel IP67 single point load cell;
◎Suitable for platform, belt and other electronic scales;
◎Maximum platform size: 50kg-1t: 600 x 800 ,2t: 1000 x 1000 mm;
Available models:
Capacity | Accuracy | Full article description |
xxkg | C3 | B6G5/H6G5-C3-xxkg-3B6 |
xxkg | C3 | B6G5/H6G5-C3-xxkg-3G6 |
G:The Insulation resistance between bridge |
Specification:
Maximum capacity ( Emax) | t | 0.05/0.1/0.15/0.2/0.25/0.3/0.4/0.5/0.6/0.75/1/1.5/2 | ||
Accuracy class | C3 | |||
Maximum number of load cell intervals (nLC) | 3000 | |||
Ratio of minimum LC verification interval Y = Emax / Vmin | 10000 | |||
Combined error | %FS | ±0.020 | ||
Creep | %FS/30min | ±0.016 | ||
Temperature effect on sensitivity | %FS/10℃ | ±0.011 | ||
Temperature effect on zero | %FS/10℃ | ±0.015 | ||
Output sensitivity (= FS) | mV/V | 2.0±0.2 | ||
Input resistance | Ω | 400±20 | ||
Output resistance | Ω | 350±3.5 | ||
Insulation resistance | MΩ | ≥ 5000 (50VDC) | ||
Zero balance | %FS | ±1.5 | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Safe overload | of Emax | 150 | ||
Ultimate overload | of Emax | 300 | ||
Corer correction | 0.02%load value/100mm | |||
ATEX classification (optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD20 T73℃ | Ⅱ3G Ex nL ⅡC T4 | |
Note:"S1" output sensitivity is 2.0± 0.002mV/V, input resistance is 384 ±4 |
Dimensions in mm:
Dimension | 50kg-1t | 1.5t-2t |
L | 150(5.91) | 150(5.91) |
H | 77(3.03) | 88(3.46) |
H1 | 46(1.81) | 55(2.17) |
W | 68(2.68) | 76(2.99) |
W1 | 38(1.50) | 42(1.65) |
Wiring:
◎Adopt shielded, 4 conductor cable: Φ6.2mm;
◎Standard cable length: 3m;
Short Description:
◎Stainless/ alloy steel IP67 single point load cell;
◎Suitable for platform, belt and other electronic scales;
◎Maximum platform size: 50kg-1t: 600 x 800 ,2t: 1000 x 1000 mm;
Available models:
Capacity | Accuracy | Full article description |
xxkg | C3 | B6G5/H6G5-C3-xxkg-3B6 |
xxkg | C3 | B6G5/H6G5-C3-xxkg-3G6 |
G:The Insulation resistance between bridge |
Specification:
Maximum capacity ( Emax) | t | 0.05/0.1/0.15/0.2/0.25/0.3/0.4/0.5/0.6/0.75/1/1.5/2 | ||
Accuracy class | C3 | |||
Maximum number of load cell intervals (nLC) | 3000 | |||
Ratio of minimum LC verification interval Y = Emax / Vmin | 10000 | |||
Combined error | %FS | ±0.020 | ||
Creep | %FS/30min | ±0.016 | ||
Temperature effect on sensitivity | %FS/10℃ | ±0.011 | ||
Temperature effect on zero | %FS/10℃ | ±0.015 | ||
Output sensitivity (= FS) | mV/V | 2.0±0.2 | ||
Input resistance | Ω | 400±20 | ||
Output resistance | Ω | 350±3.5 | ||
Insulation resistance | MΩ | ≥ 5000 (50VDC) | ||
Zero balance | %FS | ±1.5 | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Safe overload | of Emax | 150 | ||
Ultimate overload | of Emax | 300 | ||
Corer correction | 0.02%load value/100mm | |||
ATEX classification (optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD20 T73℃ | Ⅱ3G Ex nL ⅡC T4 | |
Note:"S1" output sensitivity is 2.0± 0.002mV/V, input resistance is 384 ±4 |
Dimensions in mm:
Dimension | 50kg-1t | 1.5t-2t |
L | 150(5.91) | 150(5.91) |
H | 77(3.03) | 88(3.46) |
H1 | 46(1.81) | 55(2.17) |
W | 68(2.68) | 76(2.99) |
W1 | 38(1.50) | 42(1.65) |
Wiring:
◎Adopt shielded, 4 conductor cable: Φ6.2mm;
◎Standard cable length: 3m;