B6G
SAINTBOND
Short Description:
◎Stainless steel IP66 single point load cell;
◎Suitable for single or double load cell structured platform scales;
◎Recommended platform size: 600 x 600 mm;
Available models:
Capacity | Accuracy | Full article description |
xxkg | C3 | B6G-C3-xxkg-3B6 |
xxkg | C3 | B6G-C3-xxkg-3G6 |
G:The Insulation resistance between bridge circuit and shielded wire is zeroo |
Specification:
Accuracy class | C3 | |||
Output sensitivity(= FS) | mV/V | 2.0 ±0.2 | ||
Maximum capacity( Emax) | kg | 50,100, 150, 200, 250, 300, 400, 500, 600, 635 | ||
Maximum number of load cell intervals (nLC) | 3000 | |||
Ratio of minimum LC verification interval Y = Emax / Vmin | 10000 | |||
Combined error | %FS | ±0.0230 | ||
Minimum dead load | of Emax | 0 | ||
Safe overload | of Emax | 1.5 | ||
Uitimate overload | of Emax | 3 | ||
Zero balance | %FS | ±1.0% | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Input resistance | Ω | 400 ±20 | ||
Output resistance | Ω | 350±3 | ||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Storage temperature | ℃ | -40~+70 | ||
Element matenial | Stainless steel | |||
Ingress protection (according to EN 60529) | IP66 | |||
Recommended torque on fixation | N.m | M8:25 | ||
ATEX classification (optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD 20 T73℃ | Ⅱ3G Ex nL ⅡC T4 | |
Note: S1' output sensitivity is 2.0+0.002mV/V, input resistance is384±4 |
Dimensions in mm:
Wiring:
◎Shielded, 6 conductor cable;
◎Cable diameter: Φ6mm;
◎Standard cable length: 3m;
◎ Shield connected to element;
Short Description:
◎Stainless steel IP66 single point load cell;
◎Suitable for single or double load cell structured platform scales;
◎Recommended platform size: 600 x 600 mm;
Available models:
Capacity | Accuracy | Full article description |
xxkg | C3 | B6G-C3-xxkg-3B6 |
xxkg | C3 | B6G-C3-xxkg-3G6 |
G:The Insulation resistance between bridge circuit and shielded wire is zeroo |
Specification:
Accuracy class | C3 | |||
Output sensitivity(= FS) | mV/V | 2.0 ±0.2 | ||
Maximum capacity( Emax) | kg | 50,100, 150, 200, 250, 300, 400, 500, 600, 635 | ||
Maximum number of load cell intervals (nLC) | 3000 | |||
Ratio of minimum LC verification interval Y = Emax / Vmin | 10000 | |||
Combined error | %FS | ±0.0230 | ||
Minimum dead load | of Emax | 0 | ||
Safe overload | of Emax | 1.5 | ||
Uitimate overload | of Emax | 3 | ||
Zero balance | %FS | ±1.0% | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Input resistance | Ω | 400 ±20 | ||
Output resistance | Ω | 350±3 | ||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Storage temperature | ℃ | -40~+70 | ||
Element matenial | Stainless steel | |||
Ingress protection (according to EN 60529) | IP66 | |||
Recommended torque on fixation | N.m | M8:25 | ||
ATEX classification (optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD 20 T73℃ | Ⅱ3G Ex nL ⅡC T4 | |
Note: S1' output sensitivity is 2.0+0.002mV/V, input resistance is384±4 |
Dimensions in mm:
Wiring:
◎Shielded, 6 conductor cable;
◎Cable diameter: Φ6mm;
◎Standard cable length: 3m;
◎ Shield connected to element;