◎Stainless/ alloy steel IP67 single point load cell;
◎ Suitable for the pricing scales, bench scales, belt scales etc;
◎Maximum platform size: 400*400mm;
Available models:
Capacity | Accuracy | Full article description |
xxkg | C3 | B6E/H6E-C3-xxkg-2B |
xxkg | C3 | B6E/H6E-C3-xxkg-2B-S1 |
xxkg | C3 | B6E/H6E-C3-xxkg-2G |
xxkg | C3 | B6E/H6E-C3-xxkg-2G-S1 |
G:The Insulation resistance between bridge circuit and shielded wire is zero |
Specification:
Maximum capacity ( Emax) | kg | 20/30/50/75/100/150/200/250/300 | ||
Accuracy dlass | C3 | |||
Maximum number of verification intervals | 3000 | |||
Maximum number of load cell intervals (nLC) | N.maxVmin | Emax/10000 | ||
Combined error | %FS | ±0.020 | ||
Creep | %FS/30min | ±0.016 | ||
Temperature effect on sensitivity | %FS/10℃ | ±0.011 | ||
Temperature effect on zero | %FS/10℃ | ±0.015 | ||
Output sensitivity(= FS) | mV/V | 2.0+0.2 | ||
Input resistance | Ω | 400±20 | ||
Output resistance | Ω | 351±2.0 | ||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||
Zero balance | %FS | ≤ ±1.5 | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Safeoverload | of Emax | 150 | ||
Ultimate overload | of Emax | 300 | ||
Corner correction | 0.02%load value/100mm | |||
ATEX class( optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD 20 T73℃ | Ⅱ3G Ex nL ⅡC T4 | |
Note: “S1” output sensitivity is 2.0± 0.002mV/V,input resistance is 384 ±4 |
Dimensions in mm:
Wiring:
◎Adopt shielded, 4 conductor cable: Φ5mm;
◎Standard cable length: 2m;
Short Description:
◎Stainless/ alloy steel IP67 single point load cell;
◎ Suitable for the pricing scales, bench scales, belt scales etc;
◎Maximum platform size: 400*400mm;
Available models:
Capacity | Accuracy | Full article description |
xxkg | C3 | B6E/H6E-C3-xxkg-2B |
xxkg | C3 | B6E/H6E-C3-xxkg-2B-S1 |
xxkg | C3 | B6E/H6E-C3-xxkg-2G |
xxkg | C3 | B6E/H6E-C3-xxkg-2G-S1 |
G:The Insulation resistance between bridge circuit and shielded wire is zero |
Specification:
Maximum capacity ( Emax) | kg | 20/30/50/75/100/150/200/250/300 | ||
Accuracy dlass | C3 | |||
Maximum number of verification intervals | 3000 | |||
Maximum number of load cell intervals (nLC) | N.maxVmin | Emax/10000 | ||
Combined error | %FS | ±0.020 | ||
Creep | %FS/30min | ±0.016 | ||
Temperature effect on sensitivity | %FS/10℃ | ±0.011 | ||
Temperature effect on zero | %FS/10℃ | ±0.015 | ||
Output sensitivity(= FS) | mV/V | 2.0+0.2 | ||
Input resistance | Ω | 400±20 | ||
Output resistance | Ω | 351±2.0 | ||
Insulation resistance | MΩ | ≥ 5000(50VDC) | ||
Zero balance | %FS | ≤ ±1.5 | ||
Compensated temperature | ℃ | -10~+40 | ||
Operating temperature | ℃ | -35~+65 | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation maximum | V | 18(DC) | ||
Safeoverload | of Emax | 150 | ||
Ultimate overload | of Emax | 300 | ||
Corner correction | 0.02%load value/100mm | |||
ATEX class( optional) | Ⅱ1G Ex ia ⅡC T4 | Ⅱ1D Ex iaD 20 T73℃ | Ⅱ3G Ex nL ⅡC T4 | |
Note: “S1” output sensitivity is 2.0± 0.002mV/V,input resistance is 384 ±4 |
Dimensions in mm:
Wiring:
◎Adopt shielded, 4 conductor cable: Φ5mm;