SAINTBOND Industrial Measurement Solution

Column Load Cell for Bulk Orders

Factory Quote Available Custom Parameters Engineering Support

The delivers precision weighing in demanding environments. Features IP67/IP68 sealing, ±0.05% F.S. combined error, 15 m cable, and dual material options (alloy steel or stainless steel). Compliant with GB/T7551-2008 and OIML R60 standards.

Request a Factory Quote

Send Your Product Requirement

Leave your capacity, quantity, application and parameter details for a fast response within 24 hours.


The delivers precision weighing in demanding environments. Features IP67/IP68 sealing, ±0.05% F.S. combined error, 15 m cable, and dual material options (alloy steel or stainless steel). Compliant with GB/T7551-2008 and OIML R60 standards.

Description

Precision Compression Load Cell for Industrial Integration

The is engineered for reliability in electronic weighing applications where accuracy, environmental resilience, and mechanical stability are critical. This compression-type load cell supports rated loads from 0.5t to 50t and integrates into platform scales, hopper scales, automobile testing facilities, and other industrial weighing systems.

Key Technical Advantages

  • High Accuracy: ±0.05% F.S. combined error and low creep (±0.02% F.S. over 30 minutes) ensure stable, repeatable measurements under sustained load.
  • Rugged Environmental Protection: Dual-rated IP67/IP68 sealing provides full protection against dust, immersion, oil, and corrosive media — suitable for outdoor, washdown, and hazardous area use.
  • Robust Construction: Available in hermetically welded alloy steel (-A) or stainless steel (-SS) variants, offering corrosion resistance and lightning protection across diverse operating conditions.
  • Wide Operating Range: Functional from −30°C to +70°C, with minimal thermal drift (±0.02% F.S./10°C on zero and span).
  • Flexible Excitation & Signal Integrity: Optimized for 10–12 V DC excitation (max 15 V DC), with high insulation resistance (≥5000 MΩ) and matched input/output resistance for reliable signal transmission over its 15 m integrated cable.

Standards & Compliance

Designed and tested per GB/T7551-2008 and OIML R60 — internationally recognized metrological standards for load cells — supporting traceable calibration and regulatory alignment in commercial and industrial weighing systems.

Procurement & Integration Notes

This model belongs to the LC402 family of column load cells, distinguished by its anti-reversal design, self-aligning capability, and safe overload tolerance (150% F.S. maximum safe, 250% F.S. ultimate). It is suited for OEM integration, replacement sourcing, and bulk procurement where specification consistency and environmental certification matter.

FAQ

What is the combined error specification for the Column Load Cell?

±0.05% F.S.

What sealing class does the Column Load Cell meet?

IP67/IP68

What are the available element materials for the ?

Alloy steel (-A) or stainless steel (-SS)

What is the operating temperature range of the ?

−30°C to +70°C

What is the recommended excitation voltage for the ?

10–12 V DC

What is the cable length included with the ?

15 meters

What is the accuracy specification for the LC402M Column Load Cell?

The combined error is ±0.05% F.S., and creep error over 30 minutes is ±0.02% F.S.

What environmental protection does the offer?

It has dual IP67/IP68 sealing, making it dust-tight and protected against temporary or prolonged immersion in water, oil, and corrosive media.

What materials are available for the load cell element?

Two options are offered: alloy steel (-A) and stainless steel (-SS), both with hermetic welding.

What excitation voltage should be used with the ?

Recommended excitation is 10–12 V DC; maximum allowable is 15 V DC.

How long is the integrated cable on the ?

The cable length is 15 meters.

Additional information

Sensitivity

(3.0±0.1%) mV/V

Operating Temp. Range

-30~+70℃

Combined Error

±0.05% F.S

Maximum Safe Over Load

150%F.S

Creep Error (30min )

±0.02% F.S

Ultimate Over Load

250%F.S

Zero Balance

±1% F.S

Recommend Excitation

10~12V DC

Temp. Effect On Zero

±0.02% F.S/10℃

Maximum Excitation

15V DC

Temp. Effect On Span

±0.02% F.S/10℃

Sealing Class

IP67/IP68

Input Resistance

750±5 Ω

Element Material

-A: Alloy Steel, -SS: Stainless Steel

Output Resistance

702±2 Ω

Cable

Length=15m

Insulation Resistance

≥5000M Ω

Citation

GB/T7551-2008/ OIML R60

Project Support

Need Help Selecting the Right Sensor?

Send your rated load, force direction, installation space, output signal, working environment and quantity requirements. SAINTBOND can support standard product selection and OEM / ODM force sensor customization.

01

Requirement Review

Confirm load range, application scenario, force direction, installation method and signal output.

02

Model Matching

Recommend suitable standard models or evaluate whether custom structure development is needed.

03

Drawing Check

Review dimensions, mounting holes, cable outlet, connector position and equipment integration details.

04

Batch Supply

Support sample confirmation, stable manufacturing, inspection, packaging and export delivery.