Column Load Cell for Bulk Orders

Angebot ab Werk verfügbar Benutzerdefinierte Parameter Technischer Support

The delivers precision weighing in demanding environments. Features IP67/IP68 sealing, ±0.05% F.S. combined error, 15 m cable, and dual material options (alloy steel or stainless steel). Compliant with GB/T7551-2008 and OIML R60 standards.

Angebot vom Hersteller anfordern

Senden Sie uns Ihre Produktanforderungen

Geben Sie Ihre Kapazität, Menge, Anwendungsbereich und Parameterangaben an, um innerhalb von 24 Stunden eine schnelle Antwort zu erhalten.


The delivers precision weighing in demanding environments. Features IP67/IP68 sealing, ±0.05% F.S. combined error, 15 m cable, and dual material options (alloy steel or stainless steel). Compliant with GB/T7551-2008 and OIML R60 standards.

Artikelnummer: LC402M Kategorien: ,

Beschreibung

Precision Compression Load Cell for Industrial Integration

The is engineered for reliability in electronic weighing applications where accuracy, environmental resilience, and mechanical stability are critical. This compression-type load cell supports rated loads from 0.5t to 50t and integrates into platform scales, hopper scales, automobile testing facilities, and other industrial weighing systems.

Key Technical Advantages

  • High Accuracy: ±0.05% F.S. combined error and low creep (±0.02% F.S. over 30 minutes) ensure stable, repeatable measurements under sustained load.
  • Rugged Environmental Protection: Dual-rated IP67/IP68 sealing provides full protection against dust, immersion, oil, and corrosive media — suitable for outdoor, washdown, and hazardous area use.
  • Robust Construction: Available in hermetically welded alloy steel (-A) or stainless steel (-SS) variants, offering corrosion resistance and lightning protection across diverse operating conditions.
  • Wide Operating Range: Functional from −30°C to +70°C, with minimal thermal drift (±0.02% F.S./10°C on zero and span).
  • Flexible Excitation & Signal Integrity: Optimized for 10–12 V DC excitation (max 15 V DC), with high insulation resistance (≥5000 MΩ) and matched input/output resistance for reliable signal transmission over its 15 m integrated cable.

Standards & Compliance

Designed and tested per GB/T7551-2008 and OIML R60 — internationally recognized metrological standards for load cells — supporting traceable calibration and regulatory alignment in commercial and industrial weighing systems.

Procurement & Integration Notes

This model belongs to the LC402 family of column load cells, distinguished by its anti-reversal design, self-aligning capability, and safe overload tolerance (150% F.S. maximum safe, 250% F.S. ultimate). It is suited for OEM integration, replacement sourcing, and bulk procurement where specification consistency and environmental certification matter.

FAQ

What is the combined error specification for the Column Load Cell?

±0.05% F.S.

What sealing class does the Column Load Cell meet?

IP67/IP68

What are the available element materials for the ?

Alloy steel (-A) or stainless steel (-SS)

What is the operating temperature range of the ?

−30°C to +70°C

What is the recommended excitation voltage for the ?

10–12 V DC

What is the cable length included with the ?

15 meters

What is the accuracy specification for the LC402M Column Load Cell?

The combined error is ±0.05% F.S., and creep error over 30 minutes is ±0.02% F.S.

What environmental protection does the offer?

It has dual IP67/IP68 sealing, making it dust-tight and protected against temporary or prolonged immersion in water, oil, and corrosive media.

What materials are available for the load cell element?

Two options are offered: alloy steel (-A) and stainless steel (-SS), both with hermetic welding.

What excitation voltage should be used with the ?

Recommended excitation is 10–12 V DC; maximum allowable is 15 V DC.

How long is the integrated cable on the ?

The cable length is 15 meters.

Zusätzliche Informationen

Sensitivity

(3.0±0.1%) mV/V

Operating Temp. Range

-30 bis +70 °C

Combined Error

±0.05% F.S

Maximum Safe Over Load

150%F.S

Creep Error (30min )

±0.02% F.S

Ultimate Over Load

250%F.S

Zero Balance

±1% F.S

Recommend Excitation

10~12V DC

Temp. Effect On Zero

±0.02% F.S/10℃

Maximum Excitation

15V DC

Temp. Effect On Span

±0.02% F.S/10℃

Sealing Class

IP67/IP68

Input Resistance

750±5 Ω

Element Material

-A: Alloy Steel, -SS: Stainless Steel

Output Resistance

702±2 Ω

Cable

Length=15m

Insulation Resistance

≥5000M Ω

Citation

GB/T7551-2008/ OIML R60

Rezensionen

Es gibt noch keine Rezensionen.

Schreibe die erste Rezension für „Column Load Cell for Bulk Orders“

Projektunterstützung

Benötigen Sie Hilfe bei der Auswahl des richtigen Sensors?

Teilen Sie uns bitte Ihre Nennlast, die Kraftrichtung, den Einbauraum, das Ausgangssignal, die Betriebsumgebung und die Stückzahlanforderungen mit. SAINTBOND unterstützt Sie sowohl bei der Auswahl von Standardprodukten als auch bei der kundenspezifischen Anpassung von Kraftsensoren im Rahmen von OEM- und ODM-Projekten.

01

Anforderungsprüfung

Überprüfen Sie den Lastbereich, das Anwendungsszenario, die Kraftrichtung, die Montageart und den Signalausgang.

02

Modellabgleich

Empfehlen Sie geeignete Standardmodelle oder prüfen Sie, ob die Entwicklung einer maßgeschneiderten Struktur erforderlich ist.

03

Zeichnung prüfen

Überprüfen Sie die Abmessungen, Befestigungslöcher, den Kabelausgang, die Position der Steckverbinder sowie die Details zur Geräteintegration.

04

Lieferung in Chargen

Unterstützung bei der Musterfreigabe, der stabilen Fertigung, der Prüfung, der Verpackung und der Auslieferung.