10kg Load Cell Datasheet: Specifications to Check
Reference Standard: Relevant load-cell performance and measurement-system testing standards should be selected according to the final application, installation method, and validation requirements.
A 10kg load cell datasheet should confirm much more than nominal capacity when the measurement task requires force feedback in two directions. The catalog-listed LCX2001 two-axis load cell documents X- and Y-axis capacity ranges of 1kg–20kg each, placing a 10kg requirement within the recorded range on both axes. The same datasheet also defines accuracy-related behavior, electrical bridge characteristics, environmental limits, and mutual interference that should be reviewed together before the sensor is integrated into robotic or automation equipment.
10kg Load Cell Datasheet: Two-Axis Capacity Checks
For a single-axis weighing application, a capacity figure may be the first specification a buyer checks. Two-axis force measurement requires a broader review because the sensor must distinguish force applied along two measurement directions while operating as one mechanical sensing structure.
The LCX2001 datasheet lists mutual interference of ≤±2.5% F.S. This parameter deserves particular attention in a two-axis system because it documents the specified interaction between the measurement directions. It should not be confused with non-linearity, hysteresis, or repeatability; each parameter describes a different aspect of sensor behavior.
That distinction matters in applications such as force analysis, grinding, polishing, cutting, robot manufacturing, automation equipment, and parts processing, all of which are listed in the catalog context. Where equipment needs simultaneous feedback from two directions, replacing the measurement problem with two unrelated capacity numbers can obscure how the complete sensing structure behaves.
Before defining a 10kg configuration, confirm at least these questions:
- Is force required on both X and Y axes?
- Does the required 10kg range apply to one axis or both?
- Is the documented ≤±2.5% F.S. mutual interference acceptable for the measurement objective?
- Does the application require a customized overall envelope?
- Can the downstream electronics work with the sensor’s documented bridge characteristics?
These checks turn a capacity search into a usable engineering specification.

Read the LCX2001 Accuracy Specifications as a Complete Set
A datasheet becomes more useful when its accuracy rows are interpreted as separate measurement characteristics rather than compressed into one unsupported “accuracy” number.
For the LCX2001, the documented performance parameters include:
| Datasheet parameter | LCX2001 documented value | What it helps engineers review |
|---|---|---|
| No linealidad | ≤±0.3% F.S. | Deviation from an ideal response relationship |
| Histéresis | ≤±0.2% F.S. | Difference associated with loading direction/history |
| Repetibilidad | ≤±0.3% F.S. | Consistency when measurement conditions are repeated |
| Creep, 30 min | ≤±0.3% F.S./30min | Change under sustained loading over the stated period |
| Zero balance | ±1% F.S. | Initial output condition around zero load |
| Temperature effect on zero | ≤±0.03% F.S./10°C | Documented zero-related temperature behavior |
| Sensitivity temperature drift | ≤±0.03% F.S./10°C | Documented temperature effect on sensitivity |
| Mutual interference | ≤±2.5% F.S. | Interaction between the two measurement directions |
These values should remain distinct during specification review. The datasheet does not provide a combined accuracy figure based on simply adding or otherwise combining these rows, so such a value should not be invented.
For example, non-linearity concerns the relationship between applied force and sensor response, while hysteresis addresses behavior associated with the loading path. Repetibilidad addresses the ability to reproduce a response under repeated conditions. Creep introduces a time component by documenting behavior over 30 minutes.
Temperature-related specifications add another dimension. The catalog lists both temperature effect on zero ≤±0.03% F.S./10°C and sensitivity temperature drift ≤±0.03% F.S./10°C. These are not interchangeable: one concerns zero behavior and the other sensitivity behavior.
The practical engineering task is therefore to decide which of these characteristics matters most for the intended measurement sequence. A short-duration force check, a sustained force measurement, and a robot feedback application may place different emphasis on repeatability, creep, temperature behavior, and axis interaction.
Signs the Datasheet Review Is Still Incomplete
- A 10kg capacity value has been selected, but the required X/Y measurement directions have not been defined.
- Accuracy is being described with one number even though the datasheet lists separate non-linearity, hysteresis, repeatability, creep, and temperature terms.
- Cross-axis behavior has not been reviewed even though the sensor is intended to measure force in two directions.
Check Excitation, Impedance, and Rated Output
Mechanical capacity and accuracy specifications do not define the complete sensor interface. The LCX2001 is documented with bridge-level electrical characteristics that should be reviewed before signal-conditioning or acquisition hardware is finalized.
The catalog lists a rated output of 1.0–1.5mV/V and a 5–12VDC supply excitation, with 10VDC recommended. It also specifies 380±30Ω input impedance, 350±2Ω output impedance, and insulation ≥5000MΩ/100VDC.
These values describe the sensor side of the electrical interface. They do not, by themselves, prove compatibility with a particular amplifier, controller, ADC, PLC, communication protocol, or software platform.
1. Match the Interface Plan to the Documented Bridge Output
Start with the 1.0–1.5mV/V rated output and treat it as the documented sensor characteristic that downstream electronics must accommodate. Signal-conditioning hardware should be selected or configured only after its own input requirements have been checked against the sensor specification.
The important consequence is procedural rather than promotional: controller selection should follow sensor-interface definition, not the other way around. Assuming compatibility from the word “load cell” alone can leave an otherwise suitable mechanical sensor paired with unsuitable electronics.
2. Keep Excitation Within the Documented Range
The LCX2001 lists 5–12VDC excitation and identifies 10VDC as recommended. The excitation source therefore becomes part of the measurement-system design and should be documented alongside the sensor configuration.
Avoid treating excitation as an arbitrary power-supply choice. A receiving system may still require separate signal conditioning, scaling, filtering, or acquisition hardware, and none of those functions should be assumed from the sensor datasheet unless specifically documented.
3. Review Input and Output Impedance Before Hardware Selection
The listed 380±30Ω input impedance and 350±2Ω output impedance provide additional electrical information for system planning. These values should be retained in the interface specification so that downstream hardware can be evaluated against the actual bridge characteristics instead of a generic load-cell assumption.
This is particularly useful during design reviews, when mechanical, electrical, and controls teams may otherwise be working from different versions of the sensor requirements.
4. Treat Insulation as a Separate Datasheet Property
The documented insulation rating of ≥5000MΩ/100VDC is another sensor-side characteristic. It should remain separate from accuracy, bridge output, and controller-interface claims. Its presence in the datasheet does not establish a broader environmental or regulatory certification.
The safest specification process is to preserve every verified parameter in its original scope and request additional documentation when an application requires information not stated in the catalog.
Confirm Operating Limits and Mechanical Configuration
The final stage of a 10kg load-cell datasheet review is to check whether the electrical and measurement specifications can coexist with the intended mechanical and operating environment.
The LCX2001 lists an operating temperature range of -20°C to +60°C and a safe overload of 120% F.S. These are defined operating limits and should not be expanded into unverified durability, fatigue-life, impact-resistance, or service-life claims.
Material is listed as aluminum alloy / stainless steel. The catalog establishes that those material options are associated with the model, but it does not provide evidence for assigning different accuracy, corrosion resistance, fatigue behavior, or environmental durability values to each option. Material-specific performance should therefore be confirmed for the actual ordered configuration.
The catalog also states that overall dimensions can be designed and customized according to customer requirements. That can be important in compact robotic and automation installations, where available space may influence sensor integration. However, customization should not be interpreted as evidence for an unspecified dimension, mounting pattern, stiffness characteristic, or application-specific mechanical performance.

Ningbo SAINTBOND Intelligent Technology Co.,Ltd. is identified in the supplied catalog context as a China load cell and force sensor manufacturer. For the LCX2001, the useful engineering approach is to define the complete requirement before finalizing the sensor configuration: axis capacity, accuracy terms, electrical characteristics, operating limits, material option, and required overall dimensions should all be discussed as one specification.
Items to Confirm Before Finalizing a 10kg Configuration
- Confirm that 10kg falls within the required X and Y measurement ranges for the intended task.
- Record the ≤±2.5% F.S. mutual interference specification instead of reviewing each axis as though it were independent.
- Review non-linearity, hysteresis, repeatability, creep, zero balance, and temperature behavior separately.
- Confirm that planned signal-conditioning hardware can accommodate the documented 1.0–1.5mV/V rated output.
- Keep excitation within the listed 5–12VDC range and note the documented 10VDC recommendation.
- Preserve the 380±30Ω input and 350±2Ω output impedance values in the electrical interface specification.
- Check the -20°C to +60°C operating range against the actual environment.
- Treat the 120% F.S. safe overload as a documented limit, not as a substitute for application-specific mechanical analysis.
- Confirm whether the selected configuration uses aluminum alloy or stainless steel rather than assuming material-specific performance.
- Obtain the final customized dimensions and mounting details before completing the mechanical design.
A useful datasheet review therefore ends with a defined system requirement rather than a capacity match. For the verified LCX2001, a 10kg requirement is within the documented range on both measurement axes, but the engineering decision also depends on mutual interference, individual accuracy terms, bridge characteristics, environmental limits, and mechanical configuration.
Additional information about the company’s load-cell and force-sensor portfolio can be reviewed through Ningbo SAINTBOND Intelligent Technology.