100kg Load Cell Channel Mapping for LCX6013
Reference Standard: Relevant force and moment measurement documentation and performance testing standards.
A 100kg load cell can be misleading as a search label when the actual sensor measures more than one dimension. The LCX6013 documented by Ningbo SAINTBOND Intelligent Technology Co.,Ltd. is a six-axis force moment sensor / multi-axis load and torque cell. Its data should therefore be interpreted as six separately identified measurement channels rather than one generic 100kg value.
Reading a 100kg Load Cell as Six Separate Channels
This distinction matters from the first stage of data handling. A controller screen that simply displays “load = 42” removes information that is fundamental to interpreting a six-axis sensor. The operator needs to know whether the value belongs to Fx, Fy, Fz, Mx, My, or Mz, what direction convention is associated with that channel, and which scaling definition was applied.
The LCX6013 is documented for applications including industrial robots, cooperative robots, medical robots, and industrial automation measurement. In those systems, force and moment information can be relevant simultaneously. A robot contacting a workpiece, for example, may create responses along more than one measurement dimension. The software representation therefore needs to preserve the structure of the sensing task rather than compress several physical quantities into a single display field.
For broader information about industrial weighing and force measurement, the sensor should be considered as one element of a complete measurement system. Once its signal enters downstream electronics or software, clear channel semantics become essential to retaining the meaning created at the sensing element.
What the Six LCX6013 Measurement Channels Represent
The six channel names can be organized into two groups:
| Channel | Measurement dimension | Documented capacity |
|---|---|---|
| Fx | Force along the defined X direction | 100kg |
| Fy | Force along the defined Y direction | 100kg |
| Fz | Force along the defined Z direction | 100kg |
| Mx | Moment associated with the X dimension | 2kg |
| My | Moment associated with the Y dimension | 2kg |
| Mz | Moment associated with the Z dimension | 2kg |
The important point is not merely that six signals exist. The three F channels and three M channels have different measurement meanings. An analysis file that stores all six values as interchangeable “load” fields loses that distinction and creates opportunities for incorrect interpretation later.
The catalog expresses the three moment-channel capacities as 2kg. Because the available documentation does not provide a different unit definition in the evidence used here, downstream engineering records should preserve the documented notation rather than silently converting it into another torque unit. If a project requires a different engineering unit, its exact definition and conversion basis should be confirmed before the data is used for calculations or control decisions.
Likewise, X, Y, and Z labels alone are insufficient unless their physical directions are defined for the actual system. The sensor channel called Fx does not tell a future analyst which way “positive X” pointed on a particular machine. That convention belongs in the system documentation.

A useful dataset therefore carries both measurement values and measurement meaning. Channel identity, force-versus-moment classification, direction convention, engineering units, and scaling assumptions should travel with the data instead of being remembered informally by whoever configured the system.
Keep Force and Moment Channels Distinct in the Data Model
A robust data model treats Fx, Fy, Fz, Mx, My, and Mz as named measurements rather than positions in an anonymous array.
A six-value record such as 12, 4, 28, 1, 0, 2 is difficult to interpret once it leaves the original software environment. Even if the values were correct when captured, meaning can be lost when files are exported, columns are reordered, visualization software is changed, or another engineering team receives the dataset.
A stronger representation identifies each field explicitly:
- Fx — force channel, X dimension
- Fy — force channel, Y dimension
- Fz — force channel, Z dimension
- Mx — moment channel, X dimension
- My — moment channel, Y dimension
- Mz — moment channel, Z dimension
Capacity context should also remain available. For this specific LCX6013 configuration, the documented force-channel capacity is 100kg for Fx, Fy, and Fz, while the documented moment-channel capacity is 2kg for Mx, My, and Mz.
This is particularly important for visualization. Putting all six channels onto an unlabeled graph can make a moment response appear equivalent to a force response simply because the plotted lines share the same screen. The chart legend, stored metadata, and exported column names should keep the two measurement groups recognizable.
The same principle applies when information moves between a controller, logger, database, analysis package, or supervisory application. This article does not assume compatibility with any particular controller or communication product. The requirement is more fundamental: whatever system receives the measurements should preserve the identity of the six dimensions.
Signs That Channel Meaning Is Being Lost
– Exported datasets contain generic channel numbers without a maintained channel map.
– Force and moment values appear together without documented units, direction conventions, or scaling context.
These problems can produce believable-looking numbers while weakening their engineering meaning. That is more difficult to detect than a completely missing signal because the data may still appear smooth and repeatable.
Define Channel Identity, Direction, and Scaling Before Interpreting Results
Channel labeling is only the first layer. Each channel also needs a stable definition of direction and scaling.
The LCX6013 documentation lists an output sensitivity of 0.5–2.0mV/V and an excitation voltage of 3–10V. Those are sensor specifications; they do not establish compatibility with a particular controller, amplifier, data-acquisition device, software package, or conversion library.
The practical data question is whether the downstream value assigned to Fx still represents Fx after signal processing. A measurement can pass through several transformations before reaching a user interface: raw electrical response, conditioning, digitization, scaling, storage, and visualization. If a field is mislabeled or a scaling assumption is applied to the wrong channel, the resulting number can be internally consistent while representing the wrong physical dimension.
Direction conventions are equally important. For every axis, the project should define which orientation is positive and which is negative. That definition should be tied to a documented coordinate reference rather than an informal description such as “left” or “forward,” which can become ambiguous when a sensor, tool, fixture, or robot orientation changes.
Scaling information should also be attached to the correct channel instead of applied globally simply because all six measurements come from one sensor. The verified LCX6013 specifications already show that the force and moment groups do not share the same documented capacity values.

A well-structured record can therefore include the channel name, measurement class, direction convention, unit definition, scaling source, and value. The exact database or file format can vary; consistency is more important than a particular software implementation.
Checks Before Trusting Six-Axis Measurement Data
- Confirm that Fx, Fy, Fz, Mx, My, and Mz each have unique channel identifiers.
- Keep the three force channels visibly separate from the three moment channels.
- Record the positive and negative direction convention for every axis.
- Preserve the documented capacity context associated with each channel group.
- Document the engineering unit and scaling definition applied to every displayed or stored value.
- Verify that exported files retain channel names instead of replacing them with anonymous column numbers.
- Check that visualization legends match the stored channel map.
- Treat the documented 0.5–2.0mV/V sensitivity and 3–10V excitation as sensor specifications, not automatic proof of compatibility with downstream electronics.
These controls do not replace system calibration or commissioning. Their purpose is narrower: they preserve the semantic identity of the measurement after the sensor response enters the digital data path.
Interpret Cross-Axis Response With the Decoupling Design in Mind
A six-axis sensor exists specifically because real force interaction can involve several measurement dimensions. The LCX6013 documentation describes a structural decoupling design and states that there is small coupling between dimensions.
That wording is important when interpreting simultaneous channel activity. Decoupling does not justify assuming that only one channel can respond at a time, nor does the available documentation provide a numerical coupling percentage that could be used as a universal correction threshold.
When a primary force is expected along one direction and another channel also changes, several questions should be considered before assigning meaning to the secondary response. Is the second channel consistent with the actual direction of the applied load? Is a moment physically plausible in the interaction? Are the software channel assignments correct? Are the coordinate and sign conventions consistent with the sensor orientation?
Off-axis loading and dimensional coupling are therefore interpretation issues as well as mechanical issues. A response on Fy during an event expected mainly on Fz, for example, should not automatically be classified as sensor failure or as an independent primary load. The complete six-axis pattern has to be read in the context of the actual force and moment directions.
The same caution applies to the M channels. A moment response should remain identified as a moment measurement rather than being folded into the 100kg force-channel concept simply because all six channels originate from the same LCX6013.
No numerical coupling specification, compensation matrix, correction algorithm, or controller-side transformation should be inferred from the catalog statement alone. Those details would require additional verified technical documentation.
This is the central discipline in multi-axis data interpretation: preserve what each channel means before deciding what its value means. Once channel identity, direction, scaling, and force-versus-moment classification are explicit, simultaneous responses become much easier to review without confusing data organization problems with actual mechanical behavior.
Frequently Asked Questions (FAQ)
What does a six-component force load cell measure?
A six-component sensor such as the LCX6013 separates measurement into three force dimensions and three moment dimensions. For this model, the documented channels are Fx, Fy, Fz at 100kg capacity each and Mx, My, Mz at 2kg capacity each. Their identities should remain separate throughout downstream data handling.