Column Load Cell for Wholesale Buyers
The is a low-profile compression load cell engineered for high-accuracy industrial weighing. It delivers ±0.02% F.S. combined error, IP67/IP68 ingress protection, alloy or stainless steel construction, and includes a 13 m cable. Complies with GB/T7551-2008 and OIML R60 standards.
Send Your Product Requirement
Leave your capacity, quantity, application and parameter details for a fast response within 24 hours.
The is a low-profile compression load cell engineered for high-accuracy industrial weighing. It delivers ±0.02% F.S. combined error, IP67/IP68 ingress protection, alloy or stainless steel construction, and includes a 13 m cable. Complies with GB/T7551-2008 and OIML R60 standards.
Description
Engineered for Precision and Durability in Demanding Weighing Applications
The column load cell is a low-profile, compression-type force transducer designed for reliable performance in heavy-duty industrial weighing systems—including truck and rail weighbridges, silo and hopper weighing, and continuous process weighing. Its fully leak-tested welded construction, built-in surge protection, and advanced cable entry support stable operation in harsh, high-moisture, or electrically noisy environments.
Key Technical Advantages for System Integrators and OEMs
- High accuracy & stability: ±0.02% F.S. combined error and creep error (30 min), with temperature effects on zero and span limited to ±0.02% F.S./10℃—critical for long-term calibration integrity.
- Robust environmental protection: Dual-rated IP67/IP68 sealing ensures full dust-tightness and resistance to temporary or prolonged submersion—validated for outdoor and washdown-capable installations.
- Material and electrical reliability: Alloy/stainless steel sensing element, ≥5000 MΩ insulation resistance, and surge-protected design enhance longevity in industrial settings.
- Flexible integration: 13m pre-attached cable, 10–12 VDC recommended excitation (max 15 VDC), and compliance with GB/T7551-2008 and OIML R60 support global metrological acceptance and system compatibility.
Designed for Industrial Procurement and Integration
This high-precision compression load cell is suited for buyers specifying components for weighbridge retrofits, OEM scale manufacturing, bulk material handling systems, and process control instrumentation. Its rated load options (10–60 t) and deterministic performance specs—including ±0.02% F.S. combined error, IP67/IP68 sealing, and -30~+70℃ operating range—enable confident selection without over-engineering. As part of the Saintbond column load cell family, it supports scalable sourcing for commercial procurement and distributor-level supply chains.
Product Details

FAQ
What is the combined error specification for the column load cell?
±0.02% F.S.
What is the sealing class rating for the column load cell?
IP67/IP68
What is the operating temperature range for the column load cell?
-30~+70℃
What is the maximum safe overload capacity for the column load cell?
150% F.S.
What standards does the column load cell comply with?
GB/T7551-2008 and OIML R60
What is the accuracy specification for the LC404 column load cell?
The combined error is ±0.02% F.S., and creep error over 30 minutes is also ±0.02% F.S.
What environmental protection does the column load cell provide?
It has dual IP67/IP68 sealing, offering full dust protection and resistance to temporary or prolonged water submersion.
What materials are used in the sensing element of the column load cell?
The element material is alloy steel and/or stainless steel.
What is the cable length included with the column load cell?
The unit includes a 13-meter cable.
Additional information
| Sensitivity | (2.0±0.1%) mV/V |
|---|---|
| Operating Temp. Range | -30~+70℃ |
| Combined Error | ±0.02% F.S |
| Max. Safe Over Load | 150%F.S |
| Creep Error(30min) | ±0.02% F.S |
| Ultimate Over Load | 300%F.S |
| Zero Balance | ±1% F.S |
| Recommend Excitation | 10~12VDC |
| Temp. Effect On Zero | ±0.02% F.S/10℃ |
| Maximum Excitation | 15V DC |
| Temp. Effect On Span | ±0.02% F.S/10℃ |
| Sealing Class | IP67/IP68 |
| Input Resistance | 750±5 Ω |
| Element Material | Alloy /Stainless Steel |
| Output Resistance | 702±2 Ω |
| Cable | Length=13m |
| Insulation Resistance | ≥5000M Ω |
| Citation | GB/T7551-2008/ OIML R60 |
Need Help Selecting the Right Sensor?
Send your rated load, force direction, installation space, output signal, working environment and quantity requirements. SAINTBOND can support standard product selection and OEM / ODM force sensor customization.
Requirement Review
Confirm load range, application scenario, force direction, installation method and signal output.
Model Matching
Recommend suitable standard models or evaluate whether custom structure development is needed.
Drawing Check
Review dimensions, mounting holes, cable outlet, connector position and equipment integration details.
Batch Supply
Support sample confirmation, stable manufacturing, inspection, packaging and export delivery.









Reviews