Column Load Cell is a high-precision compression load cell engineered for platform scales, truck scales, and automobile testing facilities. Features IP67/IP68 sealing, ±0.05% F.S combined error, stainless steel or aluminum construction, and 10–100t rated load capacity.

Solicitar un presupuesto del fabricante

Envía tus requisitos sobre el producto

Indica la capacidad, la cantidad, la aplicación y los detalles de los parámetros para recibir una respuesta rápida en un plazo de 24 horas.


Column Load Cell is a high-precision compression load cell engineered for platform scales, truck scales, and automobile testing facilities. Features IP67/IP68 sealing, ±0.05% F.S combined error, stainless steel or aluminum construction, and 10–100t rated load capacity.

Descripción

High-Reliability Platform Scale Load Cell for Industrial Weighing Systems

The Column Load Cell delivers precision and durability for fixed-mount compression applications where environmental resilience and measurement stability are critical. Designed specifically for integration into platform scales, electronic truck scales, hopper scales, and automobile testing facilities, it combines tight metrological performance with robust mechanical construction.

Key Technical Advantages for System Integrators & OEMs

  • High accuracy specification: ±0.05% F.S combined error and ±0.02% F.S creep error (30 min) support repeatable, traceable measurements in production and calibration-critical environments.
  • Environmental protection: Dual-rated IP67/IP68 sealing ensures resistance to dust, immersion, oil, and corrosive media—suitable for outdoor, washdown, or hazardous area installations.
  • Wide operating range: Stable performance from −30°C to +70°C, with temperature effects on zero and span limited to ±0.02% F.S/10°C.
  • Robust overload tolerance: Withstands up to 150% safe overloading and 250% ultimate overload—reducing risk of damage during commissioning or unexpected load events.
  • Flexible integration: Standard cable length of 16–20 m, M8 anti-reversal screw hole option, and compatibility with LC14A mounting accessories simplify installation and alignment.

Construction & Compliance

Available in alloy steel or stainless steel (−SS variant), hermetically welded and lightning-protected per GB/T7551-2008 and OIML R60 standards. Input resistance: 450±5 Ω; output resistance: 481±2 Ω; insulation resistance ≥5000 MΩ. Recommended excitation: 10–12 V DC (max 15 V DC).

Procurement & Application Notes

This load cell is suited for commercial procurement and OEM integration—not for retail end users. Rated capacities span 10t to 100t (10Klb to 500Klb), with custom capacity options available upon request. Its column structure provides inherent self-aligning ability and mechanical stability under off-center loading conditions common in platform-scale deployments.

Product Details

Platform scale load cell detail image 1

FAQ

What is the combined error specification for the load cell?

±0.05% F.S

What is the sealing class rating?

IP67/IP68

What is the operating temperature range?

−30°C to +70°C

What are the available rated load capacities?

10t to 100t (10Klb to 500Klb), with custom capacity options available.

What material options are offered?

Alloy steel (AL) or stainless steel (−SS)

What is the maximum safe overload limit?

150% F.S

What is the ultimate overload limit?

250% F.S

What is the recommended excitation voltage?

10–12 V DC

What is the cable length?

16m to 20m

Which standards does the comply with?

GB/T7551-2008 and OIML R60

What is the accuracy specification for the LC401 load cell?

The combined error is ±0.05% F.S, and creep error over 30 minutes is ±0.02% F.S.

What environmental protection does the offer?

It has dual IP67/IP68 sealing, providing protection against dust ingress and temporary or prolonged immersion in water.

Información adicional

Sensitivity

(2.0±0.1%) mV/V

Operating Temp. Range

-30 a +70 ℃

Combined Error

±0.05% F.S

Maximum Safe Over Load

150%F.S

Creep Error ( 30min )

±0.02% F.S

Ultimate Over Load

250%F.S

Zero Balance

±1% F.S

Recommend Excitation

10~12V DC

Tco

±0.02% F.S/10℃

Maximum Excitation

15V DC

Tc Span

±0.02% F.S/10℃

Sealing Class

IP67/IP68

Input Resistance

450±5 Ω

Element Material

A: AL , -SS: SS

Output Resistance

481±2 Ω

Cable

Length=16m ~ 20m

Insulation Resistance

≥5000M Ω

Citation

GB/T7551-2008/ OIML R60

Apoyo a proyectos

¿Necesitas ayuda para elegir el sensor adecuado?

Envíanos los datos relativos a la carga nominal, la dirección de la fuerza, el espacio de instalación, la señal de salida, el entorno de trabajo y los requisitos de cantidad. SAINTBOND puede ayudarte tanto en la selección de productos estándar como en la personalización de sensores de fuerza OEM/ODM.

01

Revisión de los requisitos

Confirma el rango de carga, el escenario de aplicación, la dirección de la fuerza, el método de instalación y la salida de señal.

02

Coincidencia de modelos

Recomendar modelos estándar adecuados o evaluar si es necesario desarrollar una estructura a medida.

03

Comprobación del dibujo

Revisa las dimensiones, los orificios de montaje, la salida de cables, la posición de los conectores y los detalles de integración de los equipos.

04

Suministro por lotes

Ofrecemos servicios de confirmación de muestras, fabricación estable, inspección, envasado y entrega para la exportación.