Column Load Cell for Distributor Sourcing
Column Load Cell delivers precision and environmental resilience for demanding industrial weighing applications. Features ±0.05% F.S. combined error, IP67/IP68 sealing, wide operating temperature range (-30~+70℃), 15m cable, and dual material options (alloy steel or stainless steel).
Envía tus requisitos sobre el producto
Indica la capacidad, la cantidad, la aplicación y los detalles de los parámetros para recibir una respuesta rápida en un plazo de 24 horas.
Column Load Cell delivers precision and environmental resilience for demanding industrial weighing applications. Features ±0.05% F.S. combined error, IP67/IP68 sealing, wide operating temperature range (-30~+70℃), 15m cable, and dual material options (alloy steel or stainless steel).
Descripción
The Column Load Cell is engineered for reliability in electronic platform scales, hopper scales, automobile testing facilities, and other compression-based industrial weighing systems. Its column structure supports anti-reversal mounting and self-aligning capability — critical for stable load transmission and long-term calibration integrity.
Verified Performance for Harsh Environments
With IP67/IP68 ingress protection, hermetic welding, and resistance to oil, water, and corrosive media, the operates safely in atrocious or hazardous areas. It meets GB/T7551-2008 and OIML R60 standards, confirming compliance with international metrological requirements for load cell accuracy and stability.
Key Technical Differentiators
- High accuracy: ±0.05% F.S. combined error and ±0.02% F.S. creep error (30 min) support repeatable measurement in dynamic or long-duration weighing tasks.
- Robust overload tolerance: Withstands up to 150% safe overloading and 250% ultimate overload — reducing risk of damage during installation, maintenance, or unexpected load spikes.
- Stable thermal behavior: Temp. effect on zero and span is limited to ±0.02% F.S./10℃, minimizing drift across its full -30~+70℃ operating range.
- Flexible excitation: Compatible with 10–12V DC recommended input (up to 15V max), simplifying integration with standard industrial signal conditioners and PLCs.
- Material choice: Available in alloy steel (-A) for cost-effective strength or stainless steel (-SS) for enhanced corrosion resistance — both with identical electrical and environmental specs.
Procurement-Ready Configuration
Supplied with a 15m cable as standard, the eliminates need for field splicing in large-scale installations. Input resistance (750±5 Ω) and output resistance (702±2 Ω) are tightly controlled to ensure compatibility with standard Wheatstone bridge instrumentation. Insulation resistance ≥5000M Ω further ensures signal integrity in high-humidity or electrically noisy environments.
Product Details

FAQ
What is the combined error specification for the Column Load Cell?
±0.05% F.S.
What is the operating temperature range of the ?
-30 a +70 ℃
What ingress protection rating does the have?
IP67/IP68
What is the maximum safe overload capacity of the ?
150% F.S.
What is the ultimate overload limit for the ?
250% F.S.
What is the sensitivity of the Column Load Cell?
(3.0±0.1%) mV/V
What excitation voltage is recommended for the ?
10~12V DC
What is the insulation resistance of the ?
≥5000M Ω
Which standards does the comply with?
GB/T7551-2008 and OIML R60
What is the zero balance tolerance for the ?
±1% F.S.
What is the accuracy specification for the LC402 Column Load Cell?
The combined error is ±0.05% F.S., and creep error over 30 minutes is ±0.02% F.S.
What environmental protection does the offer?
It has IP67/IP68 sealing, making it oil-proof, waterproof, and resistant to corrosive gases and media.
Información adicional
| Sensitivity | (3.0±0.1%) mV/V |
|---|---|
| Operating Temp. Range | -30 a +70 ℃ |
| Combined Error | ±0.05% F.S |
| Maximum Safe Over Load | 150%F.S |
| Creep Error (30min ) | ±0.02% F.S |
| Ultimate Over Load | 250%F.S |
| Zero Balance | ±1% F.S |
| Recommend Excitation | 10~12V DC |
| Temp. Effect On Zero | ±0.02% F.S/10℃ |
| Maximum Excitation | 15V DC |
| Temp. Effect On Span | ±0.02% F.S/10℃ |
| Sealing Class | IP67/IP68 |
| Input Resistance | 750±5 Ω |
| Element Material | -A: Alloy Steel, -SS: Stainless Steel |
| Output Resistance | 702±2 Ω |
| Cable | Length=15m |
| Insulation Resistance | ≥5000M Ω |
| Citation | GB/T7551-2008/ OIML R60 |
¿Necesitas ayuda para elegir el sensor adecuado?
Envíanos los datos relativos a la carga nominal, la dirección de la fuerza, el espacio de instalación, la señal de salida, el entorno de trabajo y los requisitos de cantidad. SAINTBOND puede ayudarte tanto en la selección de productos estándar como en la personalización de sensores de fuerza OEM/ODM.
Revisión de los requisitos
Confirma el rango de carga, el escenario de aplicación, la dirección de la fuerza, el método de instalación y la salida de señal.
Coincidencia de modelos
Recomendar modelos estándar adecuados o evaluar si es necesario desarrollar una estructura a medida.
Comprobación del dibujo
Revisa las dimensiones, los orificios de montaje, la salida de cables, la posición de los conectores y los detalles de integración de los equipos.
Suministro por lotes
Ofrecemos servicios de confirmación de muestras, fabricación estable, inspección, envasado y entrega para la exportación.





Valoraciones
No hay valoraciones aún.