SAINTBOND – Industrielle Messtechniklösungen

Platform Scale Load Cell for Distributor Sourcing

Angebot ab Werk verfügbar Benutzerdefinierte Parameter Technischer Support

Column Load Cell is a high-precision compression load cell engineered for platform scales, truck scales, and automobile testing facilities. Features IP67/IP68 sealing, ±0.05% F.S combined error, stainless steel or aluminum construction, and 10–100t rated load capacity.

Angebot vom Hersteller anfordern

Senden Sie uns Ihre Produktanforderungen

Geben Sie Ihre Kapazität, Menge, Anwendungsbereich und Parameterangaben an, um innerhalb von 24 Stunden eine schnelle Antwort zu erhalten.


Column Load Cell is a high-precision compression load cell engineered for platform scales, truck scales, and automobile testing facilities. Features IP67/IP68 sealing, ±0.05% F.S combined error, stainless steel or aluminum construction, and 10–100t rated load capacity.

Beschreibung

High-Reliability Platform Scale Load Cell for Industrial Weighing Systems

The Column Load Cell delivers precision and durability for fixed-mount compression applications where environmental resilience and measurement stability are critical. Designed specifically for integration into platform scales, electronic truck scales, hopper scales, and automobile testing facilities, it combines tight metrological performance with robust mechanical construction.

Key Technical Advantages for System Integrators & OEMs

  • High accuracy specification: ±0.05% F.S combined error and ±0.02% F.S creep error (30 min) support repeatable, traceable measurements in production and calibration-critical environments.
  • Environmental protection: Dual-rated IP67/IP68 sealing ensures resistance to dust, immersion, oil, and corrosive media—suitable for outdoor, washdown, or hazardous area installations.
  • Wide operating range: Stable performance from −30°C to +70°C, with temperature effects on zero and span limited to ±0.02% F.S/10°C.
  • Robust overload tolerance: Withstands up to 150% safe overloading and 250% ultimate overload—reducing risk of damage during commissioning or unexpected load events.
  • Flexible integration: Standard cable length of 16–20 m, M8 anti-reversal screw hole option, and compatibility with LC14A mounting accessories simplify installation and alignment.

Construction & Compliance

Available in alloy steel or stainless steel (−SS variant), hermetically welded and lightning-protected per GB/T7551-2008 and OIML R60 standards. Input resistance: 450±5 Ω; output resistance: 481±2 Ω; insulation resistance ≥5000 MΩ. Recommended excitation: 10–12 V DC (max 15 V DC).

Procurement & Application Notes

This load cell is suited for commercial procurement and OEM integration—not for retail end users. Rated capacities span 10t to 100t (10Klb to 500Klb), with custom capacity options available upon request. Its column structure provides inherent self-aligning ability and mechanical stability under off-center loading conditions common in platform-scale deployments.

Product Details

Platform scale load cell detail image 1

FAQ

What is the combined error specification for the load cell?

±0.05% F.S

What is the sealing class rating?

IP67/IP68

What is the operating temperature range?

−30°C to +70°C

What are the available rated load capacities?

10t to 100t (10Klb to 500Klb), with custom capacity options available.

What material options are offered?

Alloy steel (AL) or stainless steel (−SS)

What is the maximum safe overload limit?

150% F.S

What is the ultimate overload limit?

250% F.S

What is the recommended excitation voltage?

10–12 V DC

What is the cable length?

16m to 20m

Which standards does the comply with?

GB/T7551-2008 and OIML R60

What is the accuracy specification for the LC401 load cell?

The combined error is ±0.05% F.S, and creep error over 30 minutes is ±0.02% F.S.

What environmental protection does the offer?

It has dual IP67/IP68 sealing, providing protection against dust ingress and temporary or prolonged immersion in water.

Zusätzliche Informationen

Sensitivity

(2.0±0.1%) mV/V

Operating Temp. Range

-30 bis +70 °C

Combined Error

±0.05% F.S

Maximum Safe Over Load

150%F.S

Creep Error ( 30min )

±0.02% F.S

Ultimate Over Load

250%F.S

Zero Balance

±1% F.S

Recommend Excitation

10~12V DC

Tco

±0.02% F.S/10℃

Maximum Excitation

15V DC

Tc Span

±0.02% F.S/10℃

Sealing Class

IP67/IP68

Input Resistance

450±5 Ω

Element Material

A: AL , -SS: SS

Output Resistance

481±2 Ω

Cable

Length=16m ~ 20m

Insulation Resistance

≥5000M Ω

Citation

GB/T7551-2008/ OIML R60

Projektunterstützung

Benötigen Sie Hilfe bei der Auswahl des richtigen Sensors?

Teilen Sie uns bitte Ihre Nennlast, die Kraftrichtung, den Einbauraum, das Ausgangssignal, die Betriebsumgebung und die Stückzahlanforderungen mit. SAINTBOND unterstützt Sie sowohl bei der Auswahl von Standardprodukten als auch bei der kundenspezifischen Anpassung von Kraftsensoren im Rahmen von OEM- und ODM-Projekten.

01

Anforderungsprüfung

Überprüfen Sie den Lastbereich, das Anwendungsszenario, die Kraftrichtung, die Montageart und den Signalausgang.

02

Modellabgleich

Empfehlen Sie geeignete Standardmodelle oder prüfen Sie, ob die Entwicklung einer maßgeschneiderten Struktur erforderlich ist.

03

Zeichnung prüfen

Überprüfen Sie die Abmessungen, Befestigungslöcher, den Kabelausgang, die Position der Steckverbinder sowie die Details zur Geräteintegration.

04

Lieferung in Chargen

Unterstützung bei der Musterfreigabe, der stabilen Fertigung, der Prüfung, der Verpackung und der Auslieferung.