SAINTBOND – Industrielle Messtechniklösungen

Column Load Cell for Wholesale Buyers

Angebot ab Werk verfügbar Benutzerdefinierte Parameter Technischer Support

The is a low-profile compression load cell engineered for high-accuracy industrial weighing. It delivers ±0.02% F.S. combined error, IP67/IP68 ingress protection, alloy or stainless steel construction, and includes a 13 m cable. Complies with GB/T7551-2008 and OIML R60 standards.

Angebot vom Hersteller anfordern

Senden Sie uns Ihre Produktanforderungen

Geben Sie Ihre Kapazität, Menge, Anwendungsbereich und Parameterangaben an, um innerhalb von 24 Stunden eine schnelle Antwort zu erhalten.


The is a low-profile compression load cell engineered for high-accuracy industrial weighing. It delivers ±0.02% F.S. combined error, IP67/IP68 ingress protection, alloy or stainless steel construction, and includes a 13 m cable. Complies with GB/T7551-2008 and OIML R60 standards.

Beschreibung

Engineered for Precision and Durability in Demanding Weighing Applications

The column load cell is a low-profile, compression-type force transducer designed for reliable performance in heavy-duty industrial weighing systems—including truck and rail weighbridges, silo and hopper weighing, and continuous process weighing. Its fully leak-tested welded construction, built-in surge protection, and advanced cable entry support stable operation in harsh, high-moisture, or electrically noisy environments.

Key Technical Advantages for System Integrators and OEMs

  • High accuracy & stability: ±0.02% F.S. combined error and creep error (30 min), with temperature effects on zero and span limited to ±0.02% F.S./10℃—critical for long-term calibration integrity.
  • Robust environmental protection: Dual-rated IP67/IP68 sealing ensures full dust-tightness and resistance to temporary or prolonged submersion—validated for outdoor and washdown-capable installations.
  • Material and electrical reliability: Alloy/stainless steel sensing element, ≥5000 MΩ insulation resistance, and surge-protected design enhance longevity in industrial settings.
  • Flexible integration: 13m pre-attached cable, 10–12 VDC recommended excitation (max 15 VDC), and compliance with GB/T7551-2008 and OIML R60 support global metrological acceptance and system compatibility.

Designed for Industrial Procurement and Integration

This high-precision compression load cell is suited for buyers specifying components for weighbridge retrofits, OEM scale manufacturing, bulk material handling systems, and process control instrumentation. Its rated load options (10–60 t) and deterministic performance specs—including ±0.02% F.S. combined error, IP67/IP68 sealing, and -30~+70℃ operating range—enable confident selection without over-engineering. As part of the Saintbond column load cell family, it supports scalable sourcing for commercial procurement and distributor-level supply chains.

Product Details

Column load cell detail image 1

FAQ

What is the combined error specification for the column load cell?

±0.02% F.S.

What is the sealing class rating for the column load cell?

IP67/IP68

What is the operating temperature range for the column load cell?

-30 bis +70 °C

What is the maximum safe overload capacity for the column load cell?

150% F.S.

What standards does the column load cell comply with?

GB/T7551-2008 and OIML R60

What is the accuracy specification for the LC404 column load cell?

The combined error is ±0.02% F.S., and creep error over 30 minutes is also ±0.02% F.S.

What environmental protection does the column load cell provide?

It has dual IP67/IP68 sealing, offering full dust protection and resistance to temporary or prolonged water submersion.

What materials are used in the sensing element of the column load cell?

The element material is alloy steel and/or stainless steel.

What is the cable length included with the column load cell?

The unit includes a 13-meter cable.

Zusätzliche Informationen

Sensitivity

(2.0±0.1%) mV/V

Operating Temp. Range

-30 bis +70 °C

Combined Error

±0.02% F.S

Max. Safe Over Load

150%F.S

Creep Error(30min)

±0.02% F.S

Ultimate Over Load

300%F.S

Zero Balance

±1% F.S

Recommend Excitation

10~12VDC

Temp. Effect On Zero

±0.02% F.S/10℃

Maximum Excitation

15V DC

Temp. Effect On Span

±0.02% F.S/10℃

Sealing Class

IP67/IP68

Input Resistance

750±5 Ω

Element Material

Alloy /Stainless Steel

Output Resistance

702±2 Ω

Cable

Length=13m

Insulation Resistance

≥5000M Ω

Citation

GB/T7551-2008/ OIML R60

Projektunterstützung

Benötigen Sie Hilfe bei der Auswahl des richtigen Sensors?

Teilen Sie uns bitte Ihre Nennlast, die Kraftrichtung, den Einbauraum, das Ausgangssignal, die Betriebsumgebung und die Stückzahlanforderungen mit. SAINTBOND unterstützt Sie sowohl bei der Auswahl von Standardprodukten als auch bei der kundenspezifischen Anpassung von Kraftsensoren im Rahmen von OEM- und ODM-Projekten.

01

Anforderungsprüfung

Überprüfen Sie den Lastbereich, das Anwendungsszenario, die Kraftrichtung, die Montageart und den Signalausgang.

02

Modellabgleich

Empfehlen Sie geeignete Standardmodelle oder prüfen Sie, ob die Entwicklung einer maßgeschneiderten Struktur erforderlich ist.

03

Zeichnung prüfen

Überprüfen Sie die Abmessungen, Befestigungslöcher, den Kabelausgang, die Position der Steckverbinder sowie die Details zur Geräteintegration.

04

Lieferung in Chargen

Unterstützung bei der Musterfreigabe, der stabilen Fertigung, der Prüfung, der Verpackung und der Auslieferung.