Platform Scale Load Cell for Distributor Sourcing
Column Load Cell is a high-precision compression load cell engineered for platform scales, truck scales, and automobile testing facilities. Features IP67/IP68 sealing, ±0.05% F.S combined error, stainless steel or aluminum construction, and 10–100t rated load capacity.
أرسل متطلبات منتجك
يرجى ذكر تفاصيل السعة والكمية والتطبيق والمعلمات للحصول على رد سريع في غضون 24 ساعة.
Column Load Cell is a high-precision compression load cell engineered for platform scales, truck scales, and automobile testing facilities. Features IP67/IP68 sealing, ±0.05% F.S combined error, stainless steel or aluminum construction, and 10–100t rated load capacity.
الوصف
High-Reliability Platform Scale Load Cell for Industrial Weighing Systems
The Column Load Cell delivers precision and durability for fixed-mount compression applications where environmental resilience and measurement stability are critical. Designed specifically for integration into platform scales, electronic truck scales, hopper scales, and automobile testing facilities, it combines tight metrological performance with robust mechanical construction.
Key Technical Advantages for System Integrators & OEMs
- High accuracy specification: ±0.05% F.S combined error and ±0.02% F.S creep error (30 min) support repeatable, traceable measurements in production and calibration-critical environments.
- Environmental protection: Dual-rated IP67/IP68 sealing ensures resistance to dust, immersion, oil, and corrosive media—suitable for outdoor, washdown, or hazardous area installations.
- Wide operating range: Stable performance from −30°C to +70°C, with temperature effects on zero and span limited to ±0.02% F.S/10°C.
- Robust overload tolerance: Withstands up to 150% safe overloading and 250% ultimate overload—reducing risk of damage during commissioning or unexpected load events.
- Flexible integration: Standard cable length of 16–20 m, M8 anti-reversal screw hole option, and compatibility with LC14A mounting accessories simplify installation and alignment.
Construction & Compliance
Available in alloy steel or stainless steel (−SS variant), hermetically welded and lightning-protected per GB/T7551-2008 and OIML R60 standards. Input resistance: 450±5 Ω; output resistance: 481±2 Ω; insulation resistance ≥5000 MΩ. Recommended excitation: 10–12 V DC (max 15 V DC).
Procurement & Application Notes
This load cell is suited for commercial procurement and OEM integration—not for retail end users. Rated capacities span 10t to 100t (10Klb to 500Klb), with custom capacity options available upon request. Its column structure provides inherent self-aligning ability and mechanical stability under off-center loading conditions common in platform-scale deployments.
Product Details

FAQ
What is the combined error specification for the load cell?
±0.05% F.S
What is the sealing class rating?
IP67/IP68
What is the operating temperature range?
−30°C to +70°C
What are the available rated load capacities?
10t to 100t (10Klb to 500Klb), with custom capacity options available.
What material options are offered?
Alloy steel (AL) or stainless steel (−SS)
What is the maximum safe overload limit?
150% F.S
What is the ultimate overload limit?
250% F.S
What is the recommended excitation voltage?
10–12 V DC
What is the cable length?
16m to 20m
Which standards does the comply with?
GB/T7551-2008 and OIML R60
What is the accuracy specification for the LC401 load cell?
The combined error is ±0.05% F.S, and creep error over 30 minutes is ±0.02% F.S.
What environmental protection does the offer?
It has dual IP67/IP68 sealing, providing protection against dust ingress and temporary or prolonged immersion in water.
معلومات إضافية
| Sensitivity | (2.0±0.1%) mV/V |
|---|---|
| Operating Temp. Range | -30~+70 درجة مئوية |
| Combined Error | ±0.05% F.S |
| Maximum Safe Over Load | 150%F.S |
| Creep Error ( 30min ) | ±0.02% F.S |
| Ultimate Over Load | 250%F.S |
| Zero Balance | ±1% F.S |
| Recommend Excitation | 10~12V DC |
| Tco | ±0.02% F.S/10℃ |
| Maximum Excitation | 15V DC |
| Tc Span | ±0.02% F.S/10℃ |
| Sealing Class | IP67/IP68 |
| Input Resistance | 450±5 Ω |
| Element Material | A: AL , -SS: SS |
| Output Resistance | 481±2 Ω |
| Cable | Length=16m ~ 20m |
| Insulation Resistance | ≥5000M Ω |
| Citation | GB/T7551-2008/ OIML R60 |
هل تحتاج إلى مساعدة في اختيار المستشعر المناسب؟
يرجى إرسال الحمولة المحددة، واتجاه القوة، ومساحة التركيب، وإشارة الخرج، وبيئة العمل، ومتطلبات الكمية. يمكن لشركة SAINTBOND تقديم الدعم في اختيار المنتجات القياسية وتخصيص مستشعرات القوة وفقًا لطلبات OEM / ODM.
مراجعة المتطلبات
تأكد من نطاق الحمل، وسيناريو الاستخدام، واتجاه القوة، وطريقة التركيب، وإخراج الإشارة.
مطابقة النماذج
تقديم توصيات بشأن النماذج القياسية المناسبة أو تقييم ما إذا كان من الضروري تطوير هيكل مخصص.
التحقق من الرسم
راجع الأبعاد، وفتحات التثبيت، ومخرج الكابلات، وموضع الموصل، وتفاصيل تكامل المعدات.
التوريد بالدفعات
دعم عملية التحقق من العينات، والتصنيع المستقر، والفحص، والتعبئة والتغليف، وتسليم الصادرات.







المراجعات
لا توجد مراجعات بعد.